Delta fault codes
Fault codes
- ABS Original position (ABS ORG Input)
- ABZ Delta reduced-wiring encoder, exclusively for Delta permanent magnet synchronous motors
- ACE ACI open
- ACI Positive feedback 4~20 mA
- ACO10 Analog current signal 0.0~20.0 mA
- ACO11 Analog current signal 0.0~20.0 mA
- AErr ACI analog signal error
- AFE PIDOpenACI
- AI1 Open (ACE)
- AI10 Open (ACE)
- AI11 Open (ACE)
- AI2 Open (ACE)
- AI3 Open (ACE)
- AL001 Overcurrent
- AL002 Overvoltage
- AL003 Undervoltage
- AL004 Motor matching error
- AL005 Regeneration error
- AL006 Overload
- AL007 Speed control error too large
- AL008 Pulse control command error
- AL009 Position control error too large
- AL010 Reserved
- AL011 CN2 communication failure
- AL012 Calibration error
- AL013 Emergency stop
- AL014 Reverse limit error
- AL015 Forward limit error
- AL016 IGBT temperature error
- AL017 Parameter memory error
- AL018 OA and OB output error
- AL019 Serial communication error
- AL020 Serial communication timeout
- AL021 Reserved
- AL022 Main circuit power supply error.
- AL023 Motor overload prewarning
- AL024 Encoder initial field error
- AL025 Encoder internal error
- AL026 Encoder internal data reliability error
- AL027 Encoder internal reset error
- AL028 Battery voltage error or internal encoder error
- AL029 Gray code error
- AL02A Encoder revolution count error
- AL02B Motor data error
- AL02C Drive overload
- AL02F Stall prevention protection
- AL030 Motor collision error
- AL031 Incorrect motor U, V, and W wiring
- AL032 Encoder vibration error
- AL033 Open circuit at the 26 PIN terminal of the position signal adapter box or motor error
- AL034 Encoder internal communication error
- AL035 Motor temperature error
- AL036 Encoder alarm status error
- AL040 Fully closed-loop position control error too large
- AL041 Optical scale open circuit
- AL042 Analog speed input voltage too high
- AL044 Drive function utilization warning
- AL045 Electronic gear ratio setting error
- AL048 OA and OB output error
- AL04C Excessive movement of the absolute linear motor after the drive is powered off causes an electrical angle error.
- AL04D Absolute linear encoder data write error
- AL04E Z-axis motor identification direction error
- AL050 Motor auto-tuning completed
- AL051 Motor auto-tuning error
- AL052 Initial field detection error
- AL053 Motor parameters not confirmed
- AL054 Switching the motor type causes parameters to exceed their ranges
- AL055 Motor field error
- AL056 Motor speed too high
- AL057 Feedback pulse loss
- AL058 Position error too large after initial field detection at power-on is complete
- AL05B Motor type setting mismatch
- AL05C Motor position feedback error
- AL05D Offset between the absolute encoder zero point and the motor field zero point (PM.010)
- AL05E Position signal adapter box communication failure
- AL060 Absolute position lost
- AL061 Encoder voltage too low
- AL062 Absolute position revolution count overflow (encoder)
- AL063 Linear scale signal error
- AL064 Encoder vibration warning
- AL065 Drive absolute position loss
- AL066 Absolute position revolution count overflow (drive)
- AL067 Motor temperature warning
- AL068 Absolute data I/O transmission error
- AL069 Motor type error
- AL06A Absolute home coordinates have not been established
- AL06B Difference between drive internal coordinates and encoder coordinates too large
- AL06E Encoder type cannot be identified
- AL06F Absolute position establishment incomplete
- AL070 Encoder operation incomplete warning
- AL071 Encoder revolution count error
- AL073 Encoder memory error
- AL074 Encoder single-turn absolute position error
- AL075 Encoder absolute turn count error
- AL077 Encoder internal error
- AL079 Encoder parameter setting incomplete error
- AL07A Encoder Z phase position lost
- AL07B Encoder memory busy
- AL07C An absolute position clear command is issued when the motor speed exceeds 200 rpm
- AL07D Power-on is repeated without clearing AL07C, causing the motor to stop
- AL07E Encoder clear program error
- AL07F Encoder version error
- AL081 Position error between the two gantry axes is too large
- AL082 Gantry function selection error
- AL083 Drive output current too large
- AL085 Regeneration setting error
- AL086 Input voltage too high
- AL087 Hardware device error
- AL088 Drive function utilization alarm
- AL089 Current sensing affected by interference
- AL08A Auto gain adjustment command error
- AL08B Stop time too short for auto gain adjustment
- AL08C Inertia estimation error during auto gain adjustment
- AL095 Regenerative resistor open or regenerative processing circuit error
- AL099 DSP Firmware upgrade
- AL09C Parameter reset failure
- AL09D Parameter transfer failure
- AL09F Capacitor charging error
- AL0A1 Regenerative braking transistor overcurrent
- AL0A2 Power module DC Bus overvoltage
- AL0A3 Power module DC Bus undervoltage
- AL0A4 Main circuit RST overvoltage
- AL0A5 Power module system overtemperature
- AL0A6 Absolute position coordinate mismatch between the drive and motor
- AL0A7 Communication error between the power module and drive module
- AL0A8 Power supply module count error
- AL0A9 Power supply module parameter write error
- AL0AA Power supply module parameter read error
- AL0AB Power supply module parameter write error or alarm record error
- AL0AD Power supply module power mismatch
- AL0C2 Overvoltage (real-time)
- AL0C5 External sensor temperature exceeds the protection upper limit
- AL0C7 External sensor temperature warning
- AL111 SDO receive overflow
- AL112 PDO receive overflow
- AL113 TxPDO transmission failure
- AL121 Error in object dictionary Index that PDO needs to access
- AL122 Access CANopen
- AL123 Access CANopen
- AL124 Access CANopen
- AL125 The object dictionary attribute that PDO needs to access is read-only and cannot be written.
- AL126 The specified object dictionary cannot be mapped to PDO
- AL127 PDO Writing to the object dictionary to be accessed is not allowed during Servo On
- AL128 Read from EEPROM
- AL129 CANopen PDO object: error when writing EEPROM
- AL12A P1.127 value out of range
- AL12B P2.124 value out of range
- AL130 EEPROM address exceeds
- AL131 EEPROM data contents
- AL132 Password error
- AL170 Bus communication timeout
- AL180 Bus communication timeout
- AL185 Communication interrupted
- AL186 Bus data transmission error
- AL201 CANopen data initialization
- AL203 Secondary platform - Task configuration number out of range
- AL207 PR command Type 8 source parameter group out of range
- AL209 PR command Type 8 source parameter group out of range
- AL211 PR command Type [8] instruction - Parameter format setting error
- AL213 PR Program parameter write error
- AL215 The parameter is read-only
- AL217 Servo ON or an invalid value. Correct the PR command and parameters
- AL219 PR command Type [8] instruction - Cannot write to a locked parameter
- AL21B Secondary platform - Memory stack out of range
- AL21D Secondary platform - Expression with a zero divisor in the program
- AL221 Secondary platform - Use of a nonexistent mode
- AL223 Secondary platform - When the servo is in the ERROR or FAULT status, it does not
- AL22D Absolute addressing cannot be performed while E-Cam is engaged
- AL231 PR Command Type 8: source monitoring item out of range
- AL235 Position counter overflow warning
- AL239 Secondary platform - LOOP_CMD argument out of range
- AL23F Secondary platform - Parameter written to an out-of-range memory address
- AL245 PR positioning timeout
- AL247 Secondary development platform - Math function called with out-of-range arguments
- AL249 PR path number too large
- AL251 Secondary development platform - Exponentiation command argument out of range
- AL255 Secondary development platform - System object ID out of range when using system objects
- AL257 Secondary development platform - System object function block ID out of range when using system objects
- AL25B Secondary development platform - Object argument format error
- AL25F Secondary development platform - Error accessing the object dictionary
- AL261 Secondary development platform - Master-only commands cannot be used when master mode is disabled
- AL262 Secondary development platform - Read/write address out of range in master mode
- AL263 Sub-Index error when accessing the CAN object
- AL267 Data range error when accessing the CAN object
- AL26d Writing to the CAN object is not allowed when Servo On
- AL271 CAN object: error writing EE-PROM
- AL283 Software forward limit
- AL285 Software reverse limit
- AL289 Position counter overflow
- AL291 Servo OFF error
- AL292 Gantry slave axis home coordinates must be re-established
- AL293 Function or command unsupported by the gantry
- AL294 Alarm on any gantry axis (ALM)
- AL295 Decoupling during gantry movement
- AL301 CANopen synchronization failure
- AL302 CANopen synchronization signal too fast
- AL303 CANopen synchronization signal timeout
- AL304 CANopen IP command failure
- AL305 SYNC Period error
- AL35F Emergency stop (during deceleration)
- AL380 Position offset alarm
- AL3CF Emergency stop
- AL3E1 Communication synchronization failure
- AL3E2 Communication synchronization signal error
- AL3E3 Communication synchronization command timeout
- AL3E4 CANopen IP command
- AL3E5 Synchronization signal period error
- AL3E7 Communication synchronization process failure
- AL3F1 Communication-based absolute position command error
- AL400 Indexing coordinate setting error
- AL401 Received the NMT Reset command during Servo On
- AL404 PR special filter setting too large
- AL406 Pressure sensor overvoltage
- AL410 Incorrect or unsupported function use
- AL411 Encoder communication failure
- AL422 Write failure due to loss of control power
- AL425 Auxiliary encoder internal error
- AL426 Auxiliary encoder internal data reliability error
- AL427 Auxiliary encoder internal reset error
- AL428 Battery voltage error or auxiliary encoder internal error
- AL429 Auxiliary encoder Gray code error
- AL42A Auxiliary encoder revolution count error
- AL432 Auxiliary encoder vibration error
- AL433 Auxiliary encoder error
- AL434 Auxiliary encoder internal communication error
- AL435 Auxiliary encoder temperature exceeds the protection upper limit
- AL436 Auxiliary encoder alarm status error
- AL463 Auxiliary optical scale signal error warning
- AL464 Auxiliary encoder vibration warning
- AL467 Auxiliary encoder temperature warning
- AL470 Auxiliary encoder read/write incomplete warning
- AL472 Auxiliary encoder overspeed
- AL473 Auxiliary encoder memory error
- AL474 Auxiliary encoder single-turn absolute position error
- AL475 Auxiliary encoder absolute turn count error
- AL477 Auxiliary encoder internal error
- AL479 Auxiliary encoder parameter setting incomplete error
- AL47A Auxiliary encoder Z phase position lost
- AL47B Auxiliary encoder memory busy
- AL500 STO function activated
- AL501 STO_A no signal
- AL502 STO_B no signal
- AL503 STO self-diagnostic error
- AL50A The STO hardware version of the drive module (DM) is too old
- AL50B The STO hardware version of the control module (CM) is too old
- AL510 Drive internal parameter update program error
- AL512 Error during drive internal parameter update
- AL513 Drive internal communication error
- AL515 Control module (CM) Servo Off function enabled
- AL516 CN10 SF1 no signal (signal lost or error occurred)
- AL517 CN10 SF2 no signal (signal lost or error occurred)
- AL520 Calculation program timeout
- AL521 Flexibility compensation parameter error
- AL600 Drive internal error
- AL601 Control module (CM) internal error
- AL611 Hiperface Encoder - Motor position error
- AL800 Drive initialization error
- AL801 Control module (CM) hardware code error
- AL802 Drive module (DM) hardware code error
- AL809 PR basic numerical calculation or secondary platform execution error
- AL810 The number of axes installed in the drive module (DM) exceeds the control module (CM) specification
- AL820 Drive module (DM) configuration change
- AL830 Incompatible firmware versions across modules
- ALB22 Second power supply module - Main circuit power supply error
- ALB86 Second power supply module - External regenerative resistor overload
- ALB95 Second power supply module - External regenerative resistor open or regenerative transistor short circuit
- ALBA1 Second power supply module - Regenerative braking transistor overcurrent
- ALBA2 Second power supply module - DC Bus overvoltage
- ALBA3 Second power supply module - DC Bus undervoltage
- ALBA5 Second power supply module - System overtemperature
- ALBA7 Then read the parameters again.
- ALBA9 Second power supply module - Parameter write error
- ALBAA Second power supply module - Parameter read error
- ALBAB Second power supply module - Parameter write error or alarm record error
- ALC31 Motor power cable open detection
- ALCDB Drive model code error
- ALD00 MITUTOYO encoder - Overspeed error
- ALD01 MITUTOYO encoder - Power-on initialization error
- ALD02 MITUTOYO encoder - Hardware error
- ALD03 MITUTOYO encoder - Absolute position detection error
- ALD04 MITUTOYO encoder - Sensor or readhead error
- ALD05 MITUTOYO encoder - Sensor signal strength error
- ALD06 MITUTOYO encoder - Sensor signal strength warning
- ALD07 MITUTOYO encoder - Temperature warning
- ALD08 BiSS C encoder - Sensor installation error
- ALD09 BiSS C encoder - Sensor installation warning
- ALD10 Hiperface encoder - Communication error
- ALD16 EnDat 2.2 encoder - Sensor installation error
- ALD17 EnDat 2.2 encoder - Sensor signal strength error
- ALD18 EnDat 2.2 encoder - Position error
- ALD19 EnDat 2.2 encoder - Overvoltage error
- ALD20 EnDat 2.2 encoder - Undervoltage error
- ALD21 EnDat 2.2 encoder - Overcurrent error
- ALD22 EnDat 2.2 encoder - Battery undervoltage error
- ALD23 EnDat 2.2 encoder - Frequency collision warning
- ALD24 EnDat 2.2 encoder - Temperature warning
- ALD25 EnDat 2.2 encoder - Sensor signal strength warning
- ALD26 EnDat 2.2 encoder - Battery undervoltage warning
- ALD27 EnDat 2.2 Encoder - Reference point error warning
- ALD28 EnDat 2.2 Encoder - Cyclic mode warning
- ALD29 EnDat 2.2 Encoder - Position limit warning
- ALD30 EnDat 2.2 Encoder - Preparation warning
- ALD31 EnDat 2.2 Encoder - Diagnostic warning
- ALE00 Fagor Encoder - CPU error
- ALE01 Fagor Encoder - Parameter error
- ALE02 Fagor Encoder - CCD error
- ALE03 Fagor Encoder - Position error
- ALE04 Fagor Encoder - Sensor signal strength warning
- ALE05 Fagor Encoder - Voltage warning
- ALE06 Fagor Encoder - Overspeed warning
- ALE07 Fagor Encoder - Temperature warning
- ALF21 Secondary platform command error
- ALF22 Password mismatch error
- ALVN AC undervoltage during operation
- ALVS AC undervoltage while stopped
- AOVN AC overvoltage during operation
- ATPF Positioning failure during estimation
- ATTv ASRAT Travel too short
- AUE Motor auto measurement error
- AUE1 Motor auto measurement error
- AUE10 Motor auto measurement error
- AUE11 Motor auto measurement error
- AUE12 Motor auto measurement error
- AUE2 Motor auto measurement error
- AUE3 Motor auto measurement error
- AUE4 Motor auto measurement error
- AUE5 Motor auto measurement error
- AUE6 Motor auto measurement error
- AUE7 Motor auto measurement error
- AUE8 Motor auto measurement error
- AUE9 Motor auto measurement error
- AUEa Motor auto measurement error
- AUEb Motor auto measurement error
- AUEc Motor auto measurement error
- AUTO Switching
- AVI Positive feedback 0~10 V
- AVO10 Analog voltage signal 0.00~10.00 V
- AVO11 Analog voltage signal 0.00~10.00 V
- AboF PG card ABZ open
- AnL ACI analog signal loss
- AnLEr Analog feedback signal error
- Aoc Short circuit in phase U detected before operation
- BF Brake error
- BST Voltage boost error
- BWAT Bandwidth estimation error
- BX1e Monitoring signal 1 triggered
- BX1n Monitoring signal 1 triggered
- BX2e Monitoring signal 2 triggered
- BX2n Monitoring signal 2 triggered
- BX3e Monitoring signal 3 triggered
- BX3n Monitoring signal 3 triggered
- BX4e Monitoring signal 4 triggered
- BX4n Monitoring signal 4 triggered
- BX5e Monitoring signal 5 triggered
- BX5n Monitoring signal 5 triggered
- BX6e Monitoring signal 6 triggered
- BX6n Monitoring signal 6 triggered
- BX7e Monitoring signal 7 triggered
- BX7n Monitoring signal 7 triggered
- BX8e Monitoring signal 8 triggered
- BX8n Monitoring signal 8 triggered
- Boc Short circuit in phase V detected before operation
- Brk External brake error
- CAdE CANop Station number error
- CAdn CANopen station number error
- CAvi Cavitation warning
- CBER Control board identification error
- CC Current clamping current clamp
- CE1 Communication error
- CE10 Communication transmission timeout
- CE2 Communication data address error
- CE3 Communication data value error
- CE4 Communication cannot be processed
- CF1 CPU data read error
- CF2 Memory read error
- CF3 Hardware circuit error.
- CFA Auto acceleration/deceleration failure
- CFrE CANop memory error
- CFrn CANopen memory error
- CGdE CANopen open
- CGdn CANopen software open
- CHbE CANopen open
- CHbn CANopen software open
- CIdE CAN index error
- CIdn CANopen index error
- CLE Cleaning program warning
- CMTE Failure to clear multi-turn information
- CP10 PU Panel timeout
- CP20 Dedicated error codes for internal communication
- CP21 Ethernet internal communication timeout
- CP22 Dedicated error codes for internal communication
- CP30 Dedicated error codes for internal communication
- CP32 Dedicated error codes for internal communication
- CP33 Dedicated error codes for internal communication
- CPL0 PLC copy: Read mode
- CPL1 PLC copy: Write mode
- CPLF PLC copy: PLC must be disabled
- CPLP PLC copy: Password error
- CPLS PLC copy: Capacity error
- CPLt PLC copy: Timeout error
- CPLv PLC copy: Version error
- CPtn CANopen format error
- CSE Diagnostic error
- CSbn CANopen SDO receive overflow
- CSdn CANopen SDO transmission timeout
- CWF Parameter copy write not complete
- CadE CANop Station number error
- Cavi Cavitation warning
- CbFE CANop hardware open circuit
- CbFn CANopen hardware open
- Cbtn CANopen Start message error warning
- CfrE CANop memory error
- ChbE CANopen open
- CidE CAN index error
- Coc Short circuit in phase W detected before operation
- D2D Communication timeout (DDTO)
- DCC System safety circuit confirmation signal input
- DCNB Neutral point imbalance
- DDTO D2D communication timeout
- DDUE D2D Communication not established
- DER AC overvoltage while stopped (AOVS DER)
- DHCP Dynamic IP
- Demo Demo mode
- EACn Ethernet number conflict
- EC3F Mail error
- ECAP Model overvoltage (ECOV)
- ECCS Checksum error
- ECCb Communication card disconnected
- ECEF Ethernet connection error
- ECFF Factory-defined error
- ECLv Communication card voltage too low
- ECOV Overvoltage in model ECAP
- ECPP Parameterization data error
- ECPi Configuration data error
- ECbF Communication card hardware open
- ECbY Communication card busy
- ECiF Critical internal error
- ECiP IP error
- ECid Communication card node error
- ECio IO connection interruption
- ECnP No power supply to communication card
- ECo1 Maximum number of communications exceeded
- ECrF Restore factory settings
- ECto Communication timeout with the drive
- ECtt Communication card test mode
- EF External terminal error
- EF1 External terminal error 1
- EF2 External terminal error 2
- EF3 External terminal error 3
- EIP Card identification is defined by the AC motor drive family identifier (EDS, old)
- EPS Emergency power supply function action detection
- EcCe Encoder communication error
- EcEr Encoder error.
- EcLB Encoder battery low
- EcMc Encoder multi-turn error
- EcNP The encoder has no power.
- EcOF Encoder multi-turn overflow
- EcSc Encoder single-turn error
- Eco0 Maximum number of communications exceeded
- Ectt Communication card test mode
- EdtE Ethenet communication timeout
- Edtn Ethernet communication timeout
- EiSe Encoder signal error
- EiTe Encoder initialization error
- Eitn Ethernet internal communication timeout
- EnDat Communication with absolute position encoder
- EoL1 Electronic thermal relay 1 protection
- EoL2 Electronic thermal relay 2 protection
- EoL3 Electronic thermal relay 3 protection tripped
- EoL4 Electronic thermal relay 4 protection tripped
- EoL7 AH Electronic thermal relay 7 protection
- EoL8 BH Electronic thermal relay 8 protection
- EoOF Encoder multi-turn overflow
- EpSe Encoder power supply error
- FAnP Fan power supply error
- FF1 Fan 1 error
- FF12 Fans 1, 2 error
- FF123 Fan 1, 2, 3 error
- FF13 Fans 1, 3 error
- FF2 Fan 2 error
- FF23 Fans 2, 3 error
- FF3 Fan 3 error
- FFo All fans error
- FIRE Fire mode output (Fire)
- FStp Forced stop
- FXXXX AH phase-lock frequency PLL Frequency
- Fan Fan error
- FbE PID feedback error
- FbL Feedback signal error
- FirE Fire mode output
- Fire Fire mode output
- FobF Flux linkage estimator failure
- FuSE Fuse blown
- Fv Drive circuit undervoltage protection
- GFF Ground fault protection circuit activated.
- HAND Switching
- HOA Will auto-switch back to 0
- HPF Homing sequence error
- HPF1 Protection circuit error
- HPF2 Protection circuit error
- HPF3 Protection circuit error
- HPF4 Protection circuit error
- HPL Forward hardware limit warning
- HPS High water pressure
- HU Display motor angular speed
- Hd0 cc hardware circuit error
- Hd1 oc hardware circuit error
- Hd2 ov Hardware circuit error
- Hd3 occ hardware circuit error
- Hd6 oc hardware circuit error
- High Slot 2 inverter 2000h
- HmOE Excessive deviation during home return
- HnL Reverse hardware limit warning
- HotP Thermal cutout triggered
- IDCH Model code changed
- IDDE Board identification error during initialization
- IM Static auto-tuning
- INDX Index Pulse failure
- INTR MCU Control timing error
- IPCM Interpolation mode command failure
- IPM Start using high-frequency injection
- IPTE Incorrect interpolation time setting
- JAME Blocked water pipe
- JsAT Inertia estimation error
- Kbps Delta proprietary
- LBAt Battery undervoltage
- LDC Control voltage too low
- LEKE Excessive water leakage error
- LEKn Water leakage warning
- LEr Pulse tuning inductance value error
- LMIT Limit encountered during homing error
- LPS Low water pressure
- LPSE Low water pressure
- LPSn Low water pressure warning
- LV Undervoltage (indicator flashes five times, then pauses for two seconds)
- LVN DC undervoltage during operation
- LiT Limit error encountered
- Low Slot 14 inverter 2001h
- Lv Undervoltage alarm
- LvA Undervoltage during acceleration
- LvS Undervoltage while stopped
- LvX Auto error clearing (0: disabled / 1: enabled)
- Lvd Undervoltage during deceleration
- Lvn Undervoltage during constant-speed operation
- M1035 Internal node communication control
- MBF Mechanical brake feedback error
- MCF Electromagnetic contactor error
- MCOL Controller computational overload
- MErr Model error
- MI6 Count input
- MI7 Single-phase input
- MI8 Single-phase pulse input
- MO1 Multifunction output
- MO2 Multifunction output
- MPHL Output phase loss
- Macro Application macro - user-defined
- Mbps Delta proprietary
- MoTo Motor code error
- NCON N phase wiring error
- NL Reverse limit switch
- NOut Output disabled warning
- NoMo No motion control function
- OC Overcurrent (indicator flashes once, then pauses for two seconds)
- OCC Only frame D
- OH Overheat (indicator flashes four times, then pauses for two seconds)
- OL Overload
- OL3 OL3 overload
- OLD Overload
- OPH1 Output phase U loss
- OPH2 Output phase loss in phase V
- OPH3 Output phase loss in phase W
- OPHL Output phase loss warning
- ORG Switch
- OT1 Overtorque
- OT2 Overtorque
- OV Overvoltage (indicator flashes twice, then pauses for two seconds)
- OVD Lower capacitor overvoltage
- OVN DC overvoltage during operation
- OVS DC overvoltage while stopped
- OVU Upper capacitor overvoltage
- Off Open circuit
- On Conducting
- OrP Input phase loss protection
- P2P Position mode 3: Homing mode
- PCAd CAN/M station number error
- PCCt CAN/M cycle timeout
- PCE Phase wiring error
- PCGd CAN/M software connection open
- PCSF CAN/MSDO overflow
- PCSd CAN/MSDO timeout
- PCTo CAN/M communication timeout
- PCbF CAN/M software connection open
- PCnL CAN/M node error
- PGEr PG feedback signal error
- PGErr PG feedback signal error
- PGF1 PG feedback setting error
- PGF2 PG feedback open
- PGF3 PG feedback stall
- PGF4 PG slip error
- PGF5 PG card hardware error
- PGFb PG feedback error
- PGcd Wiring error
- PHL Input phase loss
- PID PID feedback signal error
- PL Forward limit switch
- PLCr PLCMCR command error
- PLE Phase-lock error
- PLFF Parameter error during operation
- PLFn Downloaded parameter error
- PLSn Checksum error
- PLSv PLC Download storage error
- PLdF PLC download error
- PLiC Internal communication error
- PLod PLC download error
- PLor PLC register overflow
- PLrt KeypadRTC timeout
- PMCF Power board communication error
- POCF Power board communication initialization error
- POTO Power-on sequence initialization timeout
- PSEr Door opening/closing limit signal error
- PSFE PROFINET storage device error
- PStE PROFINET start error
- PU Panel timeout (CP10)
- Pal Parallel operation error
- Pcod Password error
- PcodE Password error
- PgCe PG command error
- PgMr PG card multi-turn position read error
- PoF Position counter overflow
- PoPE PROFINET operation error
- PrbE PROFINET program reload error
- PtC1 Motor PTC overheat
- RTC Time error (rtF)
- RYF Power board electromagnetic switch error
- Ratio kHz, corresponding derating / load reduction ratio
- Relay Card (6 out) (EMC-R6AA)
- RoPd Rotor position detection error
- RtLv Battery undervoltage
- RuDs Run disabled
- S1 External safety emergency stop
- S18ov STO power supply 24V too high
- S18uv STO power supply 24V too low
- S2 Internal circuit diagnostics detected an error (STL2).
- S24O STO power supply 24V too high
- S24U STO power supply 24V too low
- S5ov STO power supply 5V too high
- S5uv STO power supply 5V too low
- S6ov STO power supply 6V too high
- S6uv STO power supply 6V too low
- SADE STO sampling failure
- SAdE STO sampling failure
- SDfe Memory card format error
- SDfu Insufficient memory card storage space
- SDih Memory card function execution inhibited
- SDiv SD memory card function error
- SDto Memory card operation timeout
- SE1 Parameter copy error
- SE2 Parameter copy error
- SEAB STO run time too high
- SEAb STO execution time too high
- SEBL STO run time too low
- SEbL STO execution time too low
- SGbE STOGate check error
- SLA Slave error
- SM Locked rotor auto-tuning
- SO Output logic A
- SOFT Soft-start error
- SPC1 STO channel 1 timeout
- SPC2 STO channel 2 timeout
- SPL Forward software limit warning
- SPLV SPS model undervoltage
- SPM Start using pulse injection
- SPOV SPS model overvoltage
- SSI Communication with absolute position encoder
- STC1 STO channel 1 fault
- STC2 STO channel 2 fault
- STL1 STO missing 1
- STL2 STO missing 2
- STL3 STO missing 3
- STO Alarm locked
- STO1 Safe torque output stop 1
- STO2 Safe torque output stop 2
- STOL STO open
- STOR STOROM verification failure
- STOT STO execution timeout
- STo Safe torque off
- STo1 Safe torque output stop 1
- STo2 Safe torque output stop 2
- SToL STO open
- SToT STO execution timeout
- STor STOROM verification failure
- SdDe Excessive speed feedback deviation
- SdOr Speed feedback divergence error
- SdRv Reverse speed feedback
- SfLK PMLess locked rotor
- SnL Reverse software limit warning
- Sry Safety circuit error
- TBB Web break in tension control
- TLAT Load estimation error
- TPD Tension PID error
- TRAP CPU error 0
- ThIF Protection mechanism initialization error
- ULD Light load
- Uoc Short circuit in phase U detected before operation
- UvoF PG card UVW open
- VDC Provided by AFE2000
- VRL R phase voltage circuit open
- VSL S phase voltage circuit open
- VTL T phase voltage circuit open
- Voc Short circuit in phase V detected before operation
- WCBo Water-cooling temperature detection error
- Woc Short circuit in phase W detected before operation
- aOVS AC overvoltage warning
- b4GFF Ground fault detected before operation
- bACn Modbus station number conflict
- bEb Belt break error
- bF Braking transistor error detected
- bb External interruption
- bit14 The hardware limit has not been reached.
- boc Short circuit in phase V detected before operation
- cE01 Invalid communication command
- cE02 Invalid communication address
- cE03 Communication data length error
- cE04 Communication write to a read-only address
- cE1 Communication error (warn)
- cE10 Communication Time Out(warn)
- cE2 Communication error (warn)
- cE3 Communication error (warn)
- cE4 Communication error (warn)
- cEF Specified count reached EF
- cF1 Memory write error
- cF1.0 Write error
- cF1.1 Write error
- cF2 Memory read error
- cF2.0 Read error
- cF2.1 Read error
- cF3.0 Hardware circuit error.
- cF3.1 Hardware circuit error.
- cF3.2 Hardware circuit error.
- cF3.3 Hardware circuit error.
- cF3.4 Hardware circuit error.
- cF3.5 Hardware circuit error.
- cFA Auto acceleration/deceleration failure
- ccod Firmware version error
- ccodE Software error
- cd0 Isum current detection error
- cd1 Phase U current detection error
- cd2 Phase V current detection error
- cd3 Phase W current detection error
- coc A short circuit in phase W is detected before operation
- codE Software protection activated
- code Software or password protection
- dAUE Dry-pump curve auto measurement error
- dAvE Excessive speed deviation
- dCNB Neutral-point imbalance warning
- dEb Energy regeneration action during deceleration
- dEv PID feedback error
- doEr Door opening timeout
- dryE Dry pump
- dryn Pump dry-run warning
- feet Approximately 0.9 m
- ictE InrCOM timeout error
- ictn InrCOM timeout error
- iocb IO Card disconnected
- ms Time required from S1 / S2 activation until the AC motor drive stops output
- nHoY Homing not complete
- oC Display IGBT temperature (status display)
- oH Overheat
- oH1 IGBT module overheat
- oH2 Internal ambient overheat
- oH3 Motor overheat PTC / PT100
- oH9F Motor overtemperature fault
- oH9L Motor overtemperature warning
- oHF IGBT overheat and fan error
- oL Drive overload
- oL1 Electronic thermal overload relay
- oL2 Motor overload
- oL3 Low-frequency overload
- oPE Position control error too large
- oPEE Position control error too large
- oPHL Motor open circuit or output phase loss
- oPL1 Output phase loss: phase U
- oPL2 Output phase loss: phase V
- oPL3 Output phase loss: phase W
- oSL Excessive slip
- oc Hardware circuit error (Hd1)
- ocA Overcurrent during acceleration
- ocS Overcurrent while stopped
- occ IGBT upper and lower bridge short circuit
- ocd Overcurrent during deceleration
- ocn Overcurrent during constant-speed operation
- ocs Overcurrent while stopped
- od1 Phase U current detection error
- od2 Phase V current detection error
- od3 Phase W current detection error
- orP Phase loss protection
- ot1 Circuit error
- ot2 Circuit error
- ot3 Overtorque
- ot4 Overtorque
- ov Hardware circuit error (Hd2)
- ovA Overvoltage during acceleration
- ovS Overvoltage while stopped
- ovd Overvoltage during deceleration
- ovn Overvoltage during constant-speed operation
- ovs Overvoltage while stopped
- pLE Phase-lock error
- pulse Gate width
- rCAL The calendar requires adjustment.
- rFbE Tension control PID feedback error
- rLbr Tension control open
- rtF Real-time clock time error
- ryF Power supply electromagnetic contactor error
- sc Drive module error
- tH1o IGBT temperature measurement circuit error
- tH2o Board temperature measurement circuit error
- tH3o Ambient temperature measurement circuit error
- tHo1 Power module overheat protection circuit error
- tHo2 Internal ambient temperature overheat protection circuit error
- tUn Auto parameter measurement
- tdEv Tension PID feedback error
- uC Low current warning
- vLOS AC voltage loss
- vRES Voltage resonance
- vRL R phase voltage open warning
- vSL S phase voltage open warning
- vTL T phase voltage open warning
- ydc Motor Y-D switching error