Delta AL010 fault code meaning
Delta / AL010
Series: ASDA-A2-E
Reserved
servo drive
Meaning:
Possible causes
Source: ASDA A2-E (EtherCAT) Application Technical Manual (DELTA_IA-ASD_ASDA-A2-E_UM_TC_20221229) P124
Series: ASDA-A3, ASDA-B3, ASDA-E3, ASDA-E3C-E, ASDA-E3C-L
Voltage error during regeneration
servo drive
Meaning: An error occurred during regeneration.
Possible causes
- Condition: An error occurred during regeneration. Cause:
- During regeneration, the regenerative voltage remains at 400V for a period of time. This may be caused by incorrect regenerative resistor selection or failure to connect an external regenerative resistor.
- No regenerative resistor is used, but the user has not set the regenerative resistor capacity (P1.053) to zero.
Source: ASDA-A3 User Manual (DELTA_IA-ASD_ASDA-A3_UM_SC_20230515) P1147; ASDA-B3 User Manual (DELTA_IA-ASD_ASDA-B3_UM_SC_20250108) P885; ASDA-E3 (DELTA_IA-ASD_ASDA-E3_UM_SC_20260313) P611; ASDA-E3C-E Application Technical Manual (DELTA_IA-ASD_ASDA-E3C-E_UM_SC_20260612) P535; ASDA-E3C-L Application Technical Manual (DELTA_IA-ASD_ASDA-E3C-L_UM_SC_20260612) P407
Series: ASDA-M
Chip execution timeout
servo drive
Meaning:
Possible causes
Source: ASDA-M Application Technical Manual (DELTA_IA-ASD_ASDA-M_UM_SC_20180709) P545