Delta AL0AD fault code meaning
Delta / AL0AD
Series: ASDA-H3
Power supply module power mismatch
servo drive
Meaning:
Possible causes
Source: ASDA-H3 User Manual (DELTA_IA-ASD_ASDA-H3_UM_SC_20260428) P798
Series: ASDA-W3
Total power mismatch between drive modules (DM) and power supply module (PM)
servo drive
Meaning: 1. The total power of the drive modules exceeds the power of the power supply module. 2. The model code (VP0.002) of the power supply module (PM) has no corresponding power supply module model.
Possible causes
- Conditions:
- The total power of the drive modules exceeds the power of the power supply module.
- The model code (VP0.002) of the power supply module (PM) has no corresponding power supply module model. Cause:
- The total power of the drive modules exceeds the power of the power supply module.
- The firmware version does not support the current power supply module model.
- Hardware fault in the power supply module or drive module.
Source: ASDA-W3 Series Servo System Application Technical Manual (DELTA_IA-ASD_ASDA-W3_UM_SC_20251226) P756