Delta LEr fault code meaning
Delta / LEr
Series: C2000 Plus
Pulse tuning inductance value error
AC motor drive
Meaning: If auto-tuning of the d, q axis inductance values is repeated more than three times, a pulse tuning inductance error is detected.
Possible causes
- The motor has not been disconnected from the load.
- Incorrect motor nameplate parameter input
Source: C2000 Plus Series User Manual (DELTA_IA-MDS_C2000 Plus_UM_TC_20250522) P422
Series: C2000-R
Pulse tuning inductance value error
AC motor drive
Meaning:
Possible causes
Source: C2000-R User Manual P219
Series: CH2000
Pulse tuning inductance value error
AC motor drive
Meaning: A pulse tuning inductance error is detected when auto-tuning of the d and q axis inductances is repeated more than three times.
Possible causes
- The motor has not been disconnected from the load.
- Incorrect motor nameplate parameter input
Source: CH2000 Series User Manual (DELTA_IA-MDS_CH2000_UM_SC_20251030) P382