Delta AL005 fault code meaning
Delta / AL005
Series: ASDA-A2-E
Regeneration error
servo drive
Meaning:
Possible causes
Source: ASDA A2-E (EtherCAT) Application Technical Manual (DELTA_IA-ASD_ASDA-A2-E_UM_TC_20221229) P124
Series: ASDA-A3, ASDA-B3, ASDA-E3, ASDA-E3C-E, ASDA-E3C-L
Regeneration error
servo drive
Meaning: An error occurred during regeneration.
Possible causes
- Condition: An error occurred during regeneration. Cause:
- Incorrect regenerative resistor selection or no external regenerative resistor connected.
- No regenerative resistor is used, but the user has not set the regenerative resistor capacity parameter (P1.053) to zero.
- Incorrect parameter settings (P1.052, P1.053).
Source: ASDA-A3 User Manual (DELTA_IA-ASD_ASDA-A3_UM_SC_20230515) P1145; ASDA-B3 User Manual (DELTA_IA-ASD_ASDA-B3_UM_SC_20250108) P883; ASDA-E3 (DELTA_IA-ASD_ASDA-E3_UM_SC_20260313) P608; ASDA-E3C-E Application Technical Manual (DELTA_IA-ASD_ASDA-E3C-E_UM_SC_20260612) P534; ASDA-E3C-L Application Technical Manual (DELTA_IA-ASD_ASDA-E3C-L_UM_SC_20260612) P406