Delta AL083 fault code meaning
Delta / AL083
Series: ASDA-A3, ASDA-E3
Drive output current too large
servo drive
Meaning: During normal operation, if the drive output current exceeds the internal firmware limit, AL083 is triggered to protect IGBT from overheating and burning out due to excessive current.
Possible causes
- Condition: During normal operation, if the drive output current exceeds the internal firmware limit, AL083 is triggered to protect IGBT from overheating and burning out due to excessive current. Cause:
- A short circuit occurs in UVW.
- Motor wiring error.
- The drive analog signal GND is affected by interference.
Source: ASDA-A3 User Manual (DELTA_IA-ASD_ASDA-A3_UM_SC_20230515) P1175; ASDA-E3 (DELTA_IA-ASD_ASDA-E3_UM_SC_20260313) P629
Series: ASDA-B3, ASDA-E3C-E, ASDA-E3C-L, ASDA-H3
Drive output current too large
servo drive
Meaning: During normal operation, if the drive output current exceeds the internal firmware limit, this triggers
Possible causes
- Condition: During normal operation, if the drive output current exceeds the internal firmware limit, this triggers
Source: ASDA-B3 User Manual (DELTA_IA-ASD_ASDA-B3_UM_SC_20250108) P904; ASDA-E3C-E Application Technical Manual (DELTA_IA-ASD_ASDA-E3C-E_UM_SC_20260612) P553; ASDA-E3C-L Application Technical Manual (DELTA_IA-ASD_ASDA-E3C-L_UM_SC_20260612) P419; ASDA-H3 User Manual (DELTA_IA-ASD_ASDA-H3_UM_SC_20260428) P792