Delta Boc fault code meaning
Delta / Boc
Series: MP300
Short circuit in phase V detected before operation
AC motor drive
Meaning: A short circuit in phase V is detected during the output wiring check before the AC motor drive starts running.
Possible causes
- Motor wiring error
- Check whether faulty insulation in the motor wiring causes the output
- Short circuit
- Malfunction due to interference
- The motor cable wiring length is long.
- Increase the capacity of the AC motor drive.
- U/V/W Install a AC reactor on the output side.
- Hardware fault
- A short circuit or ground fault on the output side of the AC motor drive causes Boc.
- B1 corresponds to U, V, and W; DC- corresponds to U, V, and W
- Corresponds to U, V, and W
Source: MPD_MP300 Series User Manual (DELTA_IA-MDS_MPD_UM_SC_20260326) P432