Delta PLod fault code meaning

Delta / PLod

Series: C2000 Plus, CFP2000, CH2000, DPD-K, MH300-HS, MH300, MP300, MS300

PLC download error

AC motor drive

Meaning: PLC Download error warning

Possible causes

Source: C2000 Plus Series User Manual (DELTA_IA-MDS_C2000 Plus_UM_TC_20250522) P788; CFP2000 Series User Manual (DELTA_IA-MDS_CFP2000_UM_SC_20250731) P536; CH2000 Series User Manual (DELTA_IA-MDS_CH2000_UM_SC_20251030) P736; DPD-K Series User Manual (DPD-K user manual_20211224) P595; MH300 Series (High-Speed Models) User Manual (DELTA_IA-MDS_MH300-HS_UM_SC_20241213_v3) P440; MH300 Series User Manual (DELTA_IA-MDS_MH300_UM_TC_20260505) P674; MPD_MP300 Series User Manual (DELTA_IA-MDS_MPD_UM_SC_20260326) P332; MS300 Series User Manual (DELTA_IA-MDS_MS300_UM_TC_20260417_v2) P462

Series: CP2000

PLC Download error 2

AC motor drive

Meaning: PLC Download error warning

Possible causes

Source: CP2000 Series User Manual (DELTA_IA-MDS_CP2000_UM_SC_20250704) P648

Series: VP3000

PLC download error

AC motor drive

Meaning: A device number in the downloaded program code is out of range

Possible causes

Source: VP3000 Series User Manual (DELTA_IA-MDS_VP3000_UM_TC_20250523) P435

Series: VP3000-E

PLC download error

AC motor drive

Meaning: A device number in the downloaded program code is out of range.

Possible causes

Source: VP3000-E & VP3000-EHS User Manual (DELTA_IA-MDS_VP3000-E-VP3000-EHS_UM_SC_20260306) P400