Delta ocn fault code meaning
Delta / ocn
Series: C2000-R, VFD-ED
Overcurrent during constant-speed operation
AC motor drive
Meaning:
Possible causes
Source: C2000-R User Manual P217; VFD-ED Series User Manual (DELTA_IA-MDS_VFD-ED_UM_SC_20170315) P124
Series: CT2000
Overcurrent at constant speed
AC motor drive
Meaning:
Possible causes
Source: CT2000 Series User Manual (DELTA_IA-MDS_CT2000_UM_SC_20250522) P247
Series: HES-C
Overcurrent during operation
hydraulic servo drive
Meaning:
Possible causes
Source: HES-C Technical Manual (DELTA_IA-MDS_VFD-HES_UM_TC_20250715) P100
Series: MS300
Overcurrent during constant-speed operation
AC motor drive
Meaning: During constant-speed operation, the output current exceeds 3 times the rated current of the AC motor drive. When ocn occurs, the AC motor drive output is immediately shut off, the motor coasts, and the panel displays the ocn error.
Possible causes
- Check whether faulty insulation in the motor wiring causes the output
- Short circuit
- B1 corresponds to U, V, and W; DC- corresponds to U, V, and W
- Corresponds to U, V, and W
- Used on the output side of the AC motor drive (U / V / W)
- Electromagnetic contactor opening and closing control
Source: MS300 Series User Manual (DELTA_IA-MDS_MS300_UM_TC_20260417_v2) P246
Series: MS300-HS, VFD-BP, VFD-BW, VFD-DD, VFD-E, VFD-EL-W, VFD-FE, VFD-L2, VFD-M-D, VFD-MP, VFD-VE, VFD-VL
Overcurrent at constant speed
AC motor drive
Meaning:
Possible causes
Source: MS300 (high-speed model) (DELTA_IA-MDS_VFD MS300_high_UM_TC_20170306) P140; Delta VFD-BP Manual P51; Delta VFD-BW Manual P72; VFD-DD (Ver. F, S, T & V ) (DELTA_IA-MDS_VFD-DD_UM_TC_20170609) P35; Delta VFD-E Manual P52; VFD-EL-W Series User Manual P57; Delta VFD-FE Manual P41; Delta VFD-L2 Manual P2; Delta VFD-M-D Manual P44; Delta VFD-MP Manual P41; Delta VFD-VE Manual P65; Delta VFD-VL Manual P61
Series: MX300
Overcurrent during constant-speed operation
AC motor drive
Meaning: During constant speed operation, the output current exceeds 2.5 times the rated current of the AC motor drive. When ocn occurs, the AC motor drive output is immediately disabled, the motor coasts, and the panel displays the ocn error.
Possible causes
- Faulty motor wiring insulation causes an output short circuit.
- Used on the AC motor drive output side (U/V/W)
- Electromagnetic contactor opening and closing control
- Corresponds to U, V, and W
- 8-42
Source: MX300 Series User Manual (DELTA_IA-MDS_MX300_UM_TC_20260226) P137
Series: REG2000
Overcurrent during regeneration
regenerative unit
Meaning:
Possible causes
Source: REG2000 Series User Manual (DELTA_IA-MDS_REG2000_UM_SC_20251117) P92
Series: VFD-S
Overcurrent at constant speed
AC motor drive
Meaning: Current exceeds 2 times the rated current
Possible causes
Source: Delta VFD-S Instruction Manual P47