Delta AL006 fault code meaning
Delta / AL006
Series: ASDA-A3, ASDA-B3, ASDA-E3C-E, ASDA-E3C-L, ASDA-H3
Overload
servo drive
Meaning: Motor and drive overload.
Possible causes
- Condition: Motor and drive overload. Cause:
- Continuous operation above the drive's rated load.
- Incorrect control system parameter settings.
- Incorrect motor wiring.
- Encoder error.
Source: ASDA-A3 User Manual (DELTA_IA-ASD_ASDA-A3_UM_SC_20230515) P1145; ASDA-B3 User Manual (DELTA_IA-ASD_ASDA-B3_UM_SC_20250108) P884; ASDA-E3C-E Application Technical Manual (DELTA_IA-ASD_ASDA-E3C-E_UM_SC_20260612) P534; ASDA-E3C-L Application Technical Manual (DELTA_IA-ASD_ASDA-E3C-L_UM_SC_20260612) P406; ASDA-H3 User Manual (DELTA_IA-ASD_ASDA-H3_UM_SC_20260428) P768
Series: ASDA-E3
Overload
servo drive
Meaning: Motor and drive overload.
Possible causes
- Condition: Motor and drive overload. Cause:
- Continuous operation above the rated load of the drive.
- Incorrect control system parameter settings.
- Incorrect motor or position detector wiring.
- The motor position detector is faulty.
Source: ASDA-E3 (DELTA_IA-ASD_ASDA-E3_UM_SC_20260313) P609
Series: ASDA-W3
Motor overload
servo drive
Meaning:
Possible causes
Source: ASDA-W3 Series Servo System Application Technical Manual (DELTA_IA-ASD_ASDA-W3_UM_SC_20251226) P711