Delta EcNP fault code meaning
Delta / EcNP
Series: C2000 Plus, CH2000
The encoder has no power.
AC motor drive
Meaning: An error is triggered when the encoder battery voltage falls below 2.5 V.
Possible causes
- Encoder battery depleted
- 2. Multi-turn position memory is abnormal. Perform the homing action after replacing the battery and powering on again.
- 3. If multi-turn position information is not required, the encoder can be used without a battery. Set parameter 12-23 bit0 =0 to disable battery undervoltage warning detection.
Source: C2000 Plus Series User Manual (DELTA_IA-MDS_C2000 Plus_UM_TC_20250522) P422; CH2000 Series User Manual (DELTA_IA-MDS_CH2000_UM_SC_20251030) P383
Series: C2000-R
The encoder has no power.
AC motor drive
Meaning:
Possible causes
Source: C2000-R User Manual P219