Delta AL022 fault code meaning
Delta / AL022
Series: ASDA-A3
Main circuit power supply error.
servo drive
Meaning: The main circuit power supply RST power cable may be loose, or no input power is present. The default error type for this alarm is warning (Warning). To change it to alarm (Alarm), set P2.066 [Bit 12] to 1.
Possible causes
- Condition: The main circuit power supply RST power cable may be loose, or no input power is present. The default error type for this alarm is warning (Warning). To change it to alarm (Alarm), set P2.066 [Bit 12] to 1. Cause: Main circuit power supply error.
Source: ASDA-A3 User Manual (DELTA_IA-ASD_ASDA-A3_UM_SC_20230515) P1152
Series: ASDA-B3
Main circuit power supply error.
servo drive
Meaning: Main circuit power supply RST: The power cable may be loose, or input power may be absent. The error type for this alarm defaults to warning (Warning). To change it to alarm (Alarm), set P2.066 [Bit 12] to 1.
Possible causes
- Condition: Main circuit power supply RST: The power cable may be loose, or input power may be absent. The error type for this alarm defaults to warning (Warning). To change it to alarm (Alarm), set P2.066 [Bit 12] to 1. Cause: Main circuit power supply error.
Source: ASDA-B3 User Manual (DELTA_IA-ASD_ASDA-B3_UM_SC_20250108) P889
Series: ASDA-E3
Main circuit power supply error.
servo drive
Meaning: Main circuit power supply RST: The power cable may be loose, or input power may be absent. The default severity of this alarm is warning (Warning). To change it to alarm (Alarm), set P2.066 [Bit 12] to 1.
Possible causes
- Condition: Main circuit power supply RST: The power cable may be loose, or input power may be absent. The default severity of this alarm is warning (Warning). To change it to alarm (Alarm), set P2.066 [Bit 12] to 1. Cause: Main circuit power supply error.
Source: ASDA-E3 (DELTA_IA-ASD_ASDA-E3_UM_SC_20260313) P614
Series: ASDA-E3C-E, ASDA-E3C-L
Main circuit power supply error.
servo drive
Meaning: The power cables for the main circuit power supply (L1, L2) may be loose or input power may be absent. The default classification of this alarm is warning (WARN). To classify it as an alarm (ALM), set P2.066 [Bit 12] to 1.
Possible causes
- Condition: The power cables for the main circuit power supply (L1, L2) may be loose or input power may be absent. The default classification of this alarm is warning (WARN). To classify it as an alarm (ALM), set P2.066 [Bit 12] to 1. Cause: Main circuit power supply error.
Source: ASDA-E3C-E Application Technical Manual (DELTA_IA-ASD_ASDA-E3C-E_UM_SC_20260612) P538; ASDA-E3C-L Application Technical Manual (DELTA_IA-ASD_ASDA-E3C-L_UM_SC_20260612) P410
Series: ASDA-H3
Power module main circuit power supply error
servo drive
Meaning: Main circuit power supply RST: The power cable may be loose, or no power is being supplied. The default severity of this alarm is warning (WARN). To change it to alarm (ALM), set P2.066 [Bit 12] to 1.
Possible causes
- Condition: Main circuit power supply RST: The power cable may be loose, or no power is being supplied. The default severity of this alarm is warning (WARN). To change it to alarm (ALM), set P2.066 [Bit 12] to 1. Cause: Main circuit power supply error.
Source: ASDA-H3 User Manual (DELTA_IA-ASD_ASDA-H3_UM_SC_20260428) P772
Series: ASDA-W3
Main circuit RST power supply error
servo drive
Meaning:
Possible causes
Source: ASDA-W3 Series Servo System Application Technical Manual (DELTA_IA-ASD_ASDA-W3_UM_SC_20251226) P711