Delta AL018 fault code meaning

Delta / AL018

Series: ASDA-A3, ASDA-B3, ASDA-E3C-L, ASDA-H3

OA and OB output error

servo drive

Meaning: The output pulse frequencies of OA and OB exceed the maximum hardware output frequency.

Possible causes

Source: ASDA-A3 User Manual (DELTA_IA-ASD_ASDA-A3_UM_SC_20230515) P1151; ASDA-B3 User Manual (DELTA_IA-ASD_ASDA-B3_UM_SC_20250108) P888; ASDA-E3C-L Application Technical Manual (DELTA_IA-ASD_ASDA-E3C-L_UM_SC_20260612) P410; ASDA-H3 User Manual (DELTA_IA-ASD_ASDA-H3_UM_SC_20260428) P772

Series: ASDA-E3

Position detector output error

servo drive

Meaning: The detector output pulse frequency exceeds the maximum hardware output frequency.

Possible causes

Source: ASDA-E3 (DELTA_IA-ASD_ASDA-E3_UM_SC_20260313) P613