Yaskawa fault codes
Fault codes
- A.020 Parameter checksum error
- A.021 Parameter formatting error
- A.022 System checksum error
- A.024 System alarm
- A.025 System alarm
- A.030 Main circuit detection unit error
- A.040 Parameter setting error
- A.041 Divided pulse output setting error
- A.042 Parameter combination error
- A.044 Semi-closed-loop/fully closed-loop parameter setting error
- A.046 Σ-LINK II command/response parameter setting error
- A.047 Safety mode setting error for encoder supporting functional safety
- A.04A Parameter setting error 2
- A.050 Combination error
- A.051 Alarm not supported by the product
- A.070 Motor type change detection
- A.080 Linear encoder linear scale pitch setting error
- A.0b0 Servo ON command invalid alarm
- A.100 Overcurrent detection
- A.101 Motor overcurrent detection
- A.102 Motor overcurrent detection 2
- A.119 Ground fault short circuit detected
- A.300 Regeneration error
- A.320 Regenerative overload
- A.330 Main circuit power supply wiring error
- A.400 Overvoltage
- A.410 Undervoltage
- A.42A Converter fault
- A.450 Main circuit capacitor overvoltage
- A.510 Overspeed
- A.511 Frequency-divided pulse output overspeed
- A.520 Vibration alarm
- A.521 Auto tuning alarm
- A.550 Maximum speed setting error
- A.710 Overload (instantaneous maximum load)
- A.720 Overload (continuous maximum load)
- A.729 Common to all axes
- A.730 DB overload
- A.731 DB overload
- A.740 Inrush current limiting resistor overload
- A.7A0 Heatsink overheat
- A.7A1 Internal temperature error 1
- A.7A2 Internal temperature error 2
- A.7A3 Internal temperature detection section error
- A.7Ab Servo unit built-in fan stop
- A.810 Encoder backup alarm
- A.820 Encoder checksum alarm
- A.830 Encoder battery alarm
- A.840 Encoder data alarm
- A.850 Encoder overspeed
- A.860 Encoder overheat
- A.861 Motor overheat
- A.862 Overheat alarm
- A.890 Encoder linear scale error
- A.891 Encoder module error
- A.8A0 External encoder error
- A.8A1 External encoder module error
- A.8A2 External encoder sensor fault (Incremental type)
- A.8A3 External encoder position fault (Absolute)
- A.8A5 External encoder overspeed fault
- A.8A6 External encoder overheat fault
- A.900 Excessive position deviation
- A.901 Excessive position deviation during servo ON
- A.905 Error detection warning
- A.910 Overload
- A.911 Vibration
- A.912 Internal temperature warning1
- A.913 Internal temperature warning2
- A.920 Regenerative overload
- A.921 DB overload
- A.923 Servo unit internal fan stopped
- A.929 Common to all axes
- A.930 Absolute encoder battery fault
- A.932 Σ-LINK II I/O device communication warning
- A.933 Σ-LINK II I/O device status warning
- A.93B Overheat warning
- A.941 Parameter change requiring the power supply to be switched off and on again
- A.942 Speed ripple compensation information mismatch
- A.94A Built-in controller data setting warning1(Parameter number)
- A.94C Built-in controller data setting warning3(Calculation error)
- A.94E Built-in controller data setting warning5(Latch mode error)
- A.94b Built-in controller data setting warning2(Data out of range)
- A.94d Built-in controller data setting warning4(Parameter size)
- A.95A Built-in controller command warning1(Command conditions not met)
- A.95E Built-in controller command warning5(Subcommand cannot be used)
- A.95F Built-in controller command warning6(Undefined command)
- A.95b Built-in controller command warning2(Unsupported command)
- A.95d Built-in controller command warning4(Command interference)
- A.960 MECHATROLINK communication warning
- A.971 Undervoltage
- A.97A Built-in controller command warning7(Layer error)
- A.97F MECHATROLINK communication setting warning (This alarm occurs only when MECHATROLINK-4 communication commands are used.)
- A.97b Out-of-range data clamping
- A.9A0 Overtravel
- A.9F9 INDEXER warning
- A.9b0 Preventive maintenance warning
- A.9b1 Servo motor preventive maintenance warning
- A.A9F Error
- A.AEF INDEXER module alarm
- A.C10 Loss of control detection
- A.C20 Phase error detection
- A.C21 Hall sensor fault
- A.C22 Phase information mismatch
- A.C50 Magnetic pole detection failure
- A.C51 Overtravel detection during magnetic pole detection
- A.C52 Magnetic pole detection not completed
- A.C53 Travel range exceeded during magnetic pole detection
- A.C54 Magnetic pole detection failure 2
- A.C80 Encoder clearing fault (multiturn upper limit setting error)
- A.C90 Encoder communication fault
- A.C91 Encoder communication position data acceleration error
- A.C92 Encoder communication timer error
- A.CA0 Encoder parameter error
- A.CC0 Multiturn upper limit mismatch
- A.CC1 External encoder revolution count upper limit mismatch
- A.CF1 Feedback option module communication fault (receive failure)
- A.CF2 Feedback option module communication fault (timer stopped)
- A.Cb0 Encoder feedback checksum error
- A.Cd1 Σ-LINK II node configuration error
- A.Cd2 Σ-LINK II power supply short circuit detection
- A.Cd3 Σ-LINK II configuration data checksum error
- A.Cd4 Σ-LINK II node change detection
- A.Cd7 Σ-LINK II I/O device communication error
- A.Cd8 Σ-LINK II I/O device status error
- A.E00 Built-in controller initialization timeout fault
- A.E02 Built-in controller synchronization error 1
- A.E03 Built-in controller communication data error (checksum error)
- A.E40 MECHATROLINK transmission cycle setting error
- A.E41 MECHATROLINK communication data size setting error
- A.E42 MECHATROLINK station address setting error
- A.E43 MECHATROLINK communication setting error
- A.E50 MECHATROLINK synchronization error
- A.E51 Built-in controller synchronization failure
- A.E60 MECHATROLINK communication fault (receive error)
- A.E61 Built-in controller synchronization error 4
- A.E62 MECHATROLINK Communication fault (FCS error)
- A.E63 MECHATROLINK synchronization frame not received
- A.E70 Command option module detection failure alarm
- A.E71 Safety option module detection failure alarm
- A.E72 Feedback option module detection failure alarm
- A.E73 Unsupported command option module alarm
- A.E74 Unsupported safety option module alarm
- A.E75 Unsupported feedback option module alarm
- A.E80 Command option module detection mismatch alarm
- A.E81 Safety module mismatch detected
- A.EA0 MECHATROLINK initialization timeout fault 2
- A.EA2 Built-in controller synchronization error 2
- A.EA3 Communication alarm during execution between servo units 2
- A.EC6 Safety module system error 2
- A.EC8 Gate drive error 1
- A.EC9 Gate drive error 2
- A.EF9 INDEXER alarm
- A.Eb1 Safety function signal input timing error
- A.Ed1 Built-in controller communication command timeout fault
- A.F10 Power cable phase loss
- A.F30 DB Contactor error
- A.F50 Motor main circuit cable open
- A.b10 Speed command A/D fault
- A.b11 Speed command A/D conversion data error
- A.b20 Torque command A/D error
- A.b21 Torque command A/D conversion data error
- A.b31 Current detection fault 1
- A.b32 Current detection fault 2
- A.b33 Current detection fault 3
- A.b6A MECHATROLINK communication ASIC fault 1
- A.b6b MECHATROLINK communication ASIC fault 2
- A.bE0 Firmware fault
- A.bE2 Firmware fault
- A.bF0 System alarm 0
- A.bF1 System alarm 1
- A.bF2 System alarm 2
- A.bF3 System alarm 3
- A.bF4 System alarm 4
- A.bF5 System alarm 5
- A.bF6 System alarm 6
- A.bF7 System alarm 7
- A.bF8 System alarm 8
- A.bFd System alarm D
- A.d00 Excessive position deviation
- A.d01 Excessive position deviation alarm during servo ON
- A.d02 Excessive position deviation alarm caused by speed limiting during servo ON
- A.d04 Overtravel alarm
- A.d10 Excessive deviation between motor and load positions
- A.d30 Position data too large
- AEr Station number setting fault
- AOV Power supply input overvoltage
- AUV Power supply input undervoltage
- AUv Input power supply undervoltage
- Aov Input power supply overvoltage
- BUS Option transmission error
- BUS (blinking) Option communication error (warning)
- CALL Waiting for communication
- CALL (blinking) Waiting for communication (warning)
- CE Transmission error
- CE (blinking) MEMOBUS communication error (warning)
- CF Control fault
- CONFIG RAM Enter and ROM Enter commands
- CP1 Comparator 1 out-of-range fault
- CP2 Comparator 2 out-of-range fault
- CPEr Control mode mismatch
- CPF00 Faulty control circuit
- CPF01 Faulty control circuit
- CPF02 Faulty baseblock circuit
- CPF03 Faulty EEPROM
- CPF04 The internal A/D converter of CPU is faulty
- CPF05 The external A/D converter of CPU is faulty
- CPF06 Option card connection error
- CPF07 Improper terminal circuit board connection
- CPF08 Control circuit fault
- CPF09 CPU-ASIC mutual diagnostic fault
- CPF10 Control circuit fault
- CPF11 RAM fault
- CPF12 Flash memory fault
- CPF13 Monitoring device fault
- CPF14 Control circuit fault
- CPF16 Clock fault
- CPF17 Interruption fault
- CPF18 Control circuit fault
- CPF19 Control circuit fault
- CPF20 Control circuit fault
- CPF21 Communication option card self-diagnostic error
- CPF22 Communication option card model type error
- CPF23 Improper control circuit board connection
- CPF24 Drive device signal error
- CPF25 Terminal circuit board not connected
- CPF26 Control circuit fault
- CPF27 Control circuit fault
- CPF28 Control circuit fault
- CPF29 Control circuit fault
- CPF30 Control circuit fault
- CPF31 Control circuit fault
- CPF32 Control circuit fault
- CPF33 Control circuit fault
- CPF34 Control circuit fault
- CPF35 Control circuit fault
- CPF36 Control circuit fault
- CPF37 Control circuit fault
- CPF38 Control circuit fault
- CPF39 Control circuit fault
- CPF50 Control circuit fault
- CPyE Write error
- CSEr Faulty hardware when using the copy function
- CnT1 Motor 1 start count exceeded
- CnT2 Motor 2 start count exceeded
- CnT3 Motor 3 start count exceeded
- CoF Current offset fault
- CrST External run input
- CyC MECHATROLINK transmission cycle setting fault
- CyPo Updated after restarting the power supply
- DEV Excessive speed deviation
- DEV (blinking) Excessive speed deviation (warning)
- DV1 Missing Z phase pulse detection
- DV2 Z phase noise fault detection
- DV3 Reverse rotation detection
- DV4 Reverse rotation detection 2
- DV6 The elevator car acceleration exceeds the excessive acceleration detection value (S3-16)
- E5 MECHATROLINK communication cycle setting error
- EF0 External error input from the communication option card
- EF0 (blinking) External fault input from communication option card (warning)
- EF1 External fault (input terminal S1)
- EF10 External fault (input terminal S10)
- EF11 External fault (input terminal S11)
- EF12 External fault (input terminal S12)
- EF2 External fault (input terminal S2)
- EF3 External fault (input terminal 3)
- EF3 (blinking) External fault (input terminal S3) (warning)
- EF4 External fault (input terminal S4)
- EF4 (blinking) External fault (input terminal S4) (warning)
- EF5 External fault (input terminal S5)
- EF5 (blinking) External fault (input terminal S5) (warning)
- EF6 External fault (input terminal S6)
- EF6 (blinking) External fault (input terminal S6) (warning)
- EF7 External fault (input terminal S7)
- EF7 (blinking) External fault (input terminal S7) (warning)
- EF8 External fault (input terminal S8)
- EF9 External fault (input terminal S9)
- EF (blinking) Forward and reverse commands input simultaneously (warning)
- EP24v External 24V power supply normal
- ERR Faulty EEPROM write
- End1 V/f setting too large
- End10 Rescue run magnetic pole identification warning
- End2 Incorrect motor core saturation coefficient
- End3 Improper rated current setting
- End4 Rated slip warning
- End5 Line-to-line resistance warning
- End6 Leakage inductance warning
- End7 No-load current warning
- End8 Rescue run speed warning
- End9 Rescue run magnetic pole estimation warning
- Er-01 Motor data error
- Er-02 A minor fault has occurred
- Er-03 STOP key input
- Er-04 Line-to-line resistance error
- Er-05 No-load current error.
- Er-08 Rated slip error
- Er-09 Acceleration error
- Er-10 Motor rotation direction error
- Er-11 Motor speed error
- Er-12 Current detection fault
- Er-13 Leakage inductance fault
- Er-14 Motor speed fault 2
- Er-15 Torque saturation fault
- Er-16 Inertia identification value error
- Er-17 Reverse rotation inhibited fault
- Er-18 Induced voltage fault
- Er-19 PM inductance fault
- Er-20 Armature resistor fault
- Er-21 Z phase pulse compensation amount error
- Er-22 Magnetic pole estimation error
- Er-23 Stop-type home error
- Er-24 PG-E3 characteristic fault
- Er-25 High-frequency superposition auto-tuning fault
- Err Improper EEPROM write
- F1 PG Fault detection during speed control
- FAN (blinking) Drive internal cooling fan fault (warning)
- FAn Internal air circulation fan fault
- FAn1 Drive cooling fan fault
- FDV Power supply frequency fault
- FE Ground fault
- FF01 Internal fan fault
- FF02 Motor overheat (PTC input)
- FF03 USB communication error
- FF04 Ethernet communication fault
- FF05 Control fault
- FF06 PID feedback loss
- FF07 Insufficient torque1
- FF08 Insufficient torque2
- FF09 High-slip brakingoL
- FF0E Z pulse fault
- FF0F Z pulse noise fault detection
- FF10 Reverse rotation detection
- FF11 Reverse rotation prevention detection
- FF12 Output current imbalance
- FF13 Pull-out detection
- FF14 PG hardware fault
- FF16 Speed search retry fault
- FF1C PID feedback exceeds limit
- FF1D External fault (terminal S1 input)
- FF1E External fault (terminal S2 input)
- FF1F Mechanical deterioration detection 1
- FF20 Mechanical deterioration detection 2
- FF21 Current offset fault
- FF22 PLC fault1
- FF23 PLC fault2
- FF24 DriveWorksEZ fault
- FF25 DWEZ EEPROM fault
- FF26 DriveWorksEZ fault 2
- FF27 DriveWorksEZ fault 3
- FF28 Output voltage detection fault
- FF29 Faulty installed braking resistor
- FF2A B braking transistor overload
- FF2B Motor overheat (NTC input)
- FF2C Low-speed pull-out detection
- FF2D Node Setup fault
- FF2E Thermistor open (NTC)
- FF2F Excessive acceleration detection
- FF30 MC response fault
- FF31 Start current fault
- FF32 Output current fault
- FF33 Brake response fault
- FF34 Speed command missing
- FF35 Magnetic pole identification timeout
- FF36 GF1 error
- FF37 Output phase loss 3
- FF38 Current imbalance
- FF39 Gate drive circuit board power supply undervoltage
- FF3A Power supply undervoltage
- FF3B Power supply overvoltage
- FF3C Power supply frequency fault
- FF3D Phase sequence detection fault
- FF3E Power supply undervoltage warning
- FF3F DC fuse blown
- FF40 Resonance detection
- FF41 Control circuit error
- FF42 Control circuit error
- FF43 A/D converter fault
- FF44 PWM motor fault
- FF45 EEPROM data error
- FF46 Terminal board poor contact
- FF47 EEPROM serial communication error
- FF48 RAM error
- FF49 Flash memory fault
- FF4A Control circuit fault (WDT error)
- FF4B Control circuit error
- FF4C Clock fault
- FF4D Timing sequence fault
- FF4E Control circuit fault
- FF4F Control circuit fault
- FF50 Hardware fault (at power-on)
- FF51 Hardware fault (after communication starts)
- FF52 A/D converter fault
- FF53 PWM feedback data fault
- FF54 Control circuit fault (drive capacity signal)
- FF55 Terminal circuit board not connected
- FF56 ASIC BB circuit error at start
- FF57 ASIC PWM setting register error
- FF58 ASIC PWM mode error
- FF59 ASIC start delay error
- FF5A ASIC BB turn-on error
- FF5B ASIC identification code error
- FF5C ASIC start error
- FF5D Watchdog error circuit fault
- FF5E ASIC power supply error, CPU clock error
- FF5F External A/D converter fault
- FF60 ASIC COM error
- FF61 ASIC COM error
- FF62 EEPROM data error
- FF63 Control circuit error
- FF64 Control circuit error
- FF65 Control circuit error
- FF66 Control circuit error
- FF67 Control circuit error
- FF68 Control circuit error
- FF69 Ethernet incompatibility
- FF6A Ethernet fault/connection error
- FF6C Ethernet error
- FF6D Ethernet error
- FF70 Ethernet RAM error
- FF71 Ethernet operating mode error
- FF72 Drive receive CRC error
- FF73 Drive receive frame error
- FF74 Drive receive abort error
- FF75 Ethernet receive CRC error
- FF76 Ethernet receive frame error
- FF77 Ethernet receive abort error
- FF78 COM ID error
- FF79 Type code error
- FF7A SUM check error
- FF7B Ethernet receive timeout
- FF7C Memobus timeout
- FF7D Drive receive timeout1
- FF7E CI check error
- FF7F Drive receive timeout2
- FF80 Control command selection error
- FF81 Drive receive timeout3
- FF82 Control response selection 1 error
- FF83 Drive receive timeout4
- FF84 Control response selection 2 error
- FF85 Drive receive timeout 5
- FFB4 Damping resistor overheat
- FFB5 Soft-charge discharge resistor overheat
- FFB6 Internal resistor fault
- FFB7 Safety circuit fault
- FFB8 Drive cooling fan fault
- FFC0 Comparator 1 in-range fault
- FFC1 Comparator 2 in-range fault
- FFC2 Bluetooth communication fault
- FFC3 Communication error 1
- FFC4 Communication error 2
- FFC5 Overcurrent 2
- FRL Command fault at start
- FUD DC fuse blown
- FWdL Forward run limit input active
- Fan Internal air circulation fan fault
- FbH PID feedback exceeds limit
- FbL Loss of PID feedback
- Fdv Input power supply frequency fault
- FrL Speed command loss
- GF Ground fault
- HCA Current warning
- HFb PI feedback too large
- HLCE Host transmission error
- Hbb Safety signal input active
- HbbF Safety signal input active
- KEB In operation
- L24v External 24V power supply missing
- L3 Stall prevention
- L4 Frequency detection
- L5 Fault retry
- L6 Overtorque/insufficient torque detection
- LF Output phase loss
- LF2 Output current imbalance
- LF3 Module phase loss
- LFb PI feedback decrease
- LSo Low-speed loss of synchronism fault <3>
- LT-1 Cooling fan maintenance time
- LT-2 Capacitor maintenance due
- LT-3 Inrush current prevention relay maintenance due
- LT-4 IGBT maintenance due (50%)
- LoG Log communication fault
- LoP Loss of optimal system status
- MCF Input-side electromagnetic contactor fault
- OC Overcurrent
- OH1 Heatsink overheat
- OH2 (blinking) (Warning)
- OH (blinking) Heatsink overheat (warning)
- OL1 Motor overload
- OL2 Drive overload
- OL3 Overtorque 1
- OL3 (blinking) Overtorque detection 1 (warning)
- OL4 Overtorque 2
- OL4 (blinking) Overtorque detection 2 (warning)
- OL5 Overload detection
- OL6 Light-load speed increase 2 fault
- OPE01 Drive power setting error
- OPE02 Faulty parameter setting range
- OPE03 Faulty multifunction input selection
- OPE05 Faulty option command selection
- OPE06 Faulty control method selection
- OPE07 Faulty multifunction analog input selection
- OPE08 Faulty parameter selection
- OPE10 Improper V/f data setting
- OPE11 Faulty parameter setting
- OPE13 Incorrect energy-saving control parameter settings
- OPE22 Faulty parameter setting
- OPE23 Faulty parameter setting
- OPE24 Parameter setting fault
- OPE25 Faulty settings for motor 2
- OPR Faulty operator connection
- OS Overspeed
- OS (blinking) Motor overspeed (warning)
- OV Main circuit overvoltage
- OV (blinking) Main circuit overvoltage (warning)
- PAUv Power supply undervoltage warning
- PE1 PLC detection fault
- PE2 PLC detection fault
- PF Main circuit voltage error
- PF2 Input power supply fault
- PF3 Input phase loss detection
- PFDv Power supply frequency warning
- PGO PG open detection
- PGO (blinking) PG open-circuit detection (warning)
- PSE JOHB-SMP3 protocol suite error
- PUF Fuse blown
- PWEr DWEZ password incorrect
- RH Mounted braking resistor overheat
- RR Built-in braking transistor fault
- SC Load short circuit
- SCE Incorrect short-circuit braking sequence
- SCF Safety circuit fault
- SE MEMOBUS communication test mode fault
- SE1 Run command error
- SE2 Brake release fault
- SE3 Brake response fault1
- SE4 Brake response fault2
- SE8 Sequence error 8
- SEr Speed search retry fault
- SRC Phase sequence fault
- STPo Pull-out detection
- STo Loss of synchronism detection
- SToF Safety circuit command input
- SVE Zero servo error
- SoH Buffer discharge resistor overheat
- SrC Phase sequence detection fault
- Srr Internal resistor fault
- SvE Zero servo fault
- TCA Run direction change counter alarm
- TCF Run direction change counter fault
- TCS Run direction change counter setting
- THo Thermistor open
- TiM Operator clock not set
- TrPC IGBT maintenance due (90%)
- UL3 Insufficient torque detection 1
- UL3 (blinking) Insufficient torque detection 1 (warning)
- UL4 Insufficient torque detection 2
- UL4 (blinking) Insufficient torque detection 2 (warning)
- UL5 Mechanical deterioration detection 2
- UL6 Insufficient load detection
- UNBC Current imbalance
- UV1 Main circuit undervoltage
- UV2 Control power error
- UV3 Surge prevention circuit fault
- UV (blinking) Main circuit undervoltage (warning)
- Uv Main circuit undervoltage
- Uv1 Main circuit undervoltage
- Uv2 Control power fault
- Uv3 Inrush prevention circuit fault
- Uv4 Gate drive circuit board power supply undervoltage
- WrUn Waiting to run
- bAT Operator battery low
- bCE Bluetooth communication fault
- bUS Option card communication fault
- bUSy Parameter change in progress
- bb Baseblock
- boL Braking transistor overload fault
- dCE1 Communication fault 1
- dCE2 Communication fault2
- dEv Excessive motor speed deviation
- dFPS Model mismatch
- dWA2 DriveWorksEZalarm2
- dWA3 DriveWorksEZalarm3
- dWA4 DriveWorksEZ alarm4
- dWA5 DriveWorksEZ alarm5
- dWAL DriveWorksEZ fault
- dWF1 Faulty DriveWorksEZ stored in EEPROM
- dWF2 DriveWorksEZ fault 2
- dWF3 DriveWorksEZ fault 3
- dWF4 DriveWorksEZ fault4
- dWF5 DriveWorksEZ fault5
- dWFL DriveWorksEZ fault
- doH Damping resistor overheat
- dv1 Z phase pulse loss detection
- dv2 Z phase noise fault detection
- dv3 Reverse rotation detection
- dv4 Reverse rotation prevention detection
- dv6 Excessive acceleration detection
- dv8 Initial magnetic pole estimation fault
- iFEr Communication fault
- nSE Node Setup fault
- nSS Excessive PI deviation
- ndAT Model, power supply specifications, capacity, or control mode mismatch
- oC Overcurrent
- oC2 Overcurrent 2
- oFA00 Option mismatch or improper option connection <4>
- oFA01 Improper option card connection
- oFA02 Options of the same type are installed
- oFA03 Faulty option card (CN5-A)
- oFA04 Faulty option card (CN5-A)
- oFA05 Faulty option card (CN5-A)
- oFA06 Faulty option card (CN5-A)
- oFA10 Faulty option card (CN5-A)
- oFA11 Faulty option card (CN5-A)
- oFA12 Improper option card insertion (CN5-A)
- oFA13 Improper option card insertion (CN5-A)
- oFA14 Improper option card insertion (CN5-A)
- oFA15 Improper option card insertion (CN5-A)
- oFA16 Faulty option card connection (CN5-A)
- oFA17 Faulty option card connection (CN5-A)
- oFA30 Faulty communication option card connection (CN5-A)
- oFA31 Faulty communication option card connection (CN5-A)
- oFA32 Faulty communication option card connection (CN5-A)
- oFA33 Faulty communication option card connection (CN5-A)
- oFA34 Faulty communication option card connection (CN5-A)
- oFA35 Faulty communication option card connection (CN5-A)
- oFA36 Faulty communication option card connection (CN5-A)
- oFA37 Faulty communication option card connection (CN5-A)
- oFA38 Faulty communication option card connection (CN5-A)
- oFA39 Faulty communication option card connection (CN5-A)
- oFA40 Faulty communication option card connection (CN5-A)
- oFA41 Faulty communication option card connection (CN5-A)
- oFA42 Faulty communication option card connection (CN5-A)
- oFA43 Faulty communication option card connection (CN5-A)
- oFB00 A mismatched option is connected
- oFB01 Faulty option card connection
- oFB02 Options of the same type are connected
- oFB11 Faulty option card connection (CN5-B)
- oFC00 Connected option mismatch <4>
- oFC01 Improper option card connection
- oFC02 Options of the same type connected <4>
- oFC03 Faulty option card (CN5-C)
- oFC04 Faulty option card (CN5-C)
- oFC05 Faulty option card (CN5-C)
- oFC06 Faulty option card (CN5-C)
- oFC10 Faulty option card (CN5-C)
- oFC11 Faulty option card (CN5-C)
- oFC12 Faulty option card connection (CN5-C)
- oFC13 Faulty option card connection (CN5-C)
- oFC14 Faulty option card connection (CN5-C)
- oFC15 Faulty option card connection (CN5-C)
- oFC16 Improper option card insertion (CN5-C)
- oFC17 Improper option card connection (CN5-C)
- oFC50 Faulty option card (CN5-C)
- oFC51 Faulty option card (CN5-C)
- oFC52 Faulty option card (CN5-C)
- oFC53 Faulty option card (CN5-C)
- oFC54 Faulty option card (CN5-C)
- oFC55 Faulty option card (CN5-C)
- oFb00 Connected option mismatch <4>
- oFb01 Improper option card connection
- oFb02 Options of the same type connected <4>
- oFb03 Faulty option card (CN5-B)
- oFb04 Faulty option card (CN5-B)
- oFb05 Faulty option card (CN5-B)
- oFb06 Faulty option card (CN5-B)
- oFb10 Faulty option card (CN5-B)
- oFb11 Faulty option card (CN5-B)
- oFb12 Improper option card insertion (CN5-B)
- oFb13 Improper option card insertion (CN5-B)
- oFb14 Faulty option card connection (CN5-B)
- oFb15 Improper option card insertion (CN5-B)
- oFb16 Improper option card insertion (CN5-B)
- oFb17 Improper option card insertion (CN5-B)
- oH Heatsink overheat
- oH1 Heatsink overheat
- oH2 Drive overheat prewarning
- oH3 Motor overheat warning (PTC input)
- oH4 Motor overheat fault (PTC input)
- oH5 Motor overheat (NTC input)
- oL1 Motor overload
- oL2 AC drive overload
- oL3 Overtorque detection 1
- oL4 Overtorque detection 2
- oL5 Mechanical deterioration detection 1
- oL6 Light-load speed increase 2 fault
- oL7 High-slip braking overload
- oPE01 Drive capacity setting fault
- oPE02 Parameter setting error
- oPE03 Incorrect multifunction input selection
- oPE04 Terminal circuit board replacement detection
- oPE05 Incorrect command selection
- oPE06 Incorrect control mode selection
- oPE07 Incorrect multifunction analog input selection
- oPE08 Incorrect parameter selection
- oPE09 Incorrect PID control selection
- oPE10 Incorrect V/f data setting
- oPE11 Incorrect carrier frequency setting
- oPE13 Incorrect pulse train monitoring selection
- oPE15 Incorrect torque control setting
- oPE16 Incorrect energy-saving control parameter settings
- oPE18 Incorrect online tuning parameter settings
- oPE20 Incorrect PG-F3 setting
- oPE22 Incorrect parameter settings
- oPE23 Incorrect parameter settings
- oPE24 Incorrect parameter settings
- oPE25 Incorrect parameter settings
- oPr Improper operator connection
- oS Overspeed (control mode with PG)
- ov Main circuit overvoltage
- ovEr Parameter changes exceed limit
- rEvL Run limit input active
- rF Braking resistor resistance value error
- rH Mounted braking resistor overheat
- rUn 2 motor switching command input during operation
- rdEr Read fault
- rr Built-in braking transistor fault
- vAEr Power supply specifications or capacity mismatch
- vFyE Parameter mismatch
- voF Output voltage detection fault
- vrE Resonance detection