Yaskawa OPE11 fault code meaning
Yaskawa / OPE11
Series: 616G5
Faulty parameter setting
drive
Meaning:
Possible causes
Source: Yaskawa VS-616G5 Instruction Manual: Protection and Diagnostic Functions P279
Series: L7
Improper carrier frequency parameter setting
drive
Meaning: Any of the following improper settings occurs; C6-05 (carrier frequency gain) > 6 and C6-04 (carrier frequency lower limit) > C6-03 (carrier frequency upper limit); the upper and lower limits of C6-03 and 04 are incorrect; C6-01 is 0 and C6-02 is 2–6; C6-01 is 1 and C6-02 is 7–E
Possible causes
Source: Yaskawa L7 Series Elevator Drive User Manual, Fault Diagnosis P269
Series: Varispeed G7 (Crane)
Faulty parameter setting
drive
Meaning: The upper and lower limit relationship for carrier frequency parameters C6-03 to 05 is incorrect.
Possible causes
Source: General-Purpose Drive Crane Application Software G7 Instruction Manual P53