Yaskawa OL4 fault code meaning
Yaskawa / OL4
Series: 616G5
Overtorque 2
drive
Meaning:
Possible causes
Source: Yaskawa VS-616G5 Instruction Manual: Protection and Diagnostic Functions P275
Series: L7
Overtorque detection 2
drive
Meaning: The drive output current (V/f control) or output torque (vector control) exceeds the setting (L6-05) for longer than the specified time (L6-06); detection is performed when L6-04 is set to 3 or 4; motor overload
Possible causes
Source: Yaskawa L7 Series Elevator Drive User Manual, Fault Diagnosis P262
Series: Varispeed G7 (Crane)
Overtorque detection 2
drive
Meaning: The drive output current or torque command exceeds the overtorque detection value 2(S6-05) for longer than the detection time 2(S6-06).
Possible causes
Source: General-Purpose Drive Crane Application Software G7 Instruction Manual P53