Yaskawa DV6 fault code meaning

Yaskawa / DV6

Series: L7

The elevator car acceleration exceeds the excessive acceleration detection value (S3-16)

drive

Meaning: An unconditional coast stop is performed when DV5 is detected; incorrect home pulse correction amount for PG (parameter: E5-11); noise interference in the PG cable (A/B phase); incorrect PG cable wiring; PG cable open; PG card damaged; PG (motor side) damaged; phase loss in drive output wiring; incorrect motor parameter (E5 parameter) settings

Possible causes

Source: Yaskawa L7 Series Elevator Drive Instruction Manual Fault Diagnosis P263