Yaskawa CPF03 fault code meaning

Yaskawa / CPF03

Series: 616G5

Faulty EEPROM

drive

Meaning:

Possible causes

Source: Yaskawa VS-616G5 Instruction Manual, Protection and Diagnostic Functions P276

Series: A1000, H1000, L1000A, W1000

Improper control circuit board connection

drive

Meaning:

Possible causes

Source: A1000 Series Quick Start Guide P106; H1000 Series Quick Start Guide P96; L1000A Series Quick Start Guide P115; W1000 Series Technical Manual P261

Series: D1000, D1000R

Improper control circuit board connection

drive

Meaning: Improper connection between the control circuit board and the regenerative converter.

Possible causes

Source: D1000 Series User Manual P93; D1000R Series User Manual P69

Series: ES700, GA500, GA501, GA700

Control circuit fault

drive

Meaning:

Possible causes

Source: ES700 Technical Manual P301; GA500 Technical Manual P295; GA501 Technical Manual P259; GA700 Technical Manual P358

Series: L7

Faulty EEPROM

drive

Meaning: Invalid checksum; interference or spikes occur at the control circuit input terminals, or the control board is damaged

Possible causes

Source: Yaskawa L7 Series Elevator Drive User Manual Fault Diagnosis P265

Series: R1000

Improper control circuit board connection

drive

Meaning: Improper connection between the control circuit board and the regenerative unit.

Possible causes

Source: R1000 Series User Manual P75

Series: T1000V, V1000

PWM data error

drive

Meaning:

Possible causes

Source: T1000V Series Technical Manual P228; V1000 Series Technical Manual P239