Yaskawa DEV (blinking) fault code meaning

Yaskawa / DEV (blinking)

Series: L7

Excessive speed deviation (warning)

drive

Meaning: Detected when F1-04 is set to 0, 1, or 2 and A1-02 is set to 3; speed deviation is at or above the set value (F1-10) for longer than the specified time (F1-11); load too large; acceleration/deceleration time too short; load locked; inappropriate settings of F1-10 and F1-11; brake sequence error; the motor continues to run while the brake is applied

Possible causes

Source: Yaskawa L7 Series Elevator Drive User Manual Fault Diagnosis P268