Siemens F7452 fault code meaning

Siemens / F7452

Series: V90

Following error too large

servo drive

Meaning: The difference between the position setpoint and the actual position value (dynamic following error mode) exceeds the tolerance (p2546). The value of p2546 is too small. The position loop gain is too small. The torque or acceleration capability of the drive has been exceeded. The position measuring system has an error. The position control direction is incorrect. The mechanical system is jammed. The operating speed is too high or the difference between position setpoints is too large. Identify and eliminate the cause.

Possible causes

Source: SINAMICS V90 PROFINET, SIMOTICS S-1FL6 Operating Instructions P374