Siemens F7443 fault code meaning
Siemens / F7443
Series: V90
Reference point coordinates outside the permitted range
servo drive
Meaning: The reference point coordinate received when adjusting the encoder via connector input p2599 is outside half the encoder range and cannot be set as the actual axis position. Fault value (r0949, decimal): Maximum permissible reference point coordinate. See: p2599 (EPOS Reference point coordinate value). For motors with absolute encoders, the maximum permissible encoder range is calculated using the following formulas: For multi-turn encoders: (4096 * p29247) / 2. For single-turn encoders: p29247 / 2
Possible causes
Source: SINAMICS V90 PROFINET, SIMOTICS S-1FL6 Operating Instructions P373