Siemens F7090 fault code meaning
Siemens / F7090
Series: V90
Drive: Torque upper limit is lower than the lower limit
servo drive
Meaning: The torque upper limit is less than the lower limit. The torque upper limit value (p29050) must be ≥ the torque lower limit value (p29051).
Possible causes
Source: SINAMICS V90 PROFINET, SIMOTICS S-1FL6 Operating Instructions P370