Siemens F52911 fault code meaning
Siemens / F52911
Series: V90
Forward torque limit error
servo drive
Meaning: One of the positive torque limits (P29050, p1520) is less than 0.
Possible causes
Source: SINAMICS V90 pulse, USS_Modbus, SIMOTICS S-1FL6 Operating Instructions P481