Siemens F50510 fault code meaning
Siemens / F50510
Series: G110M, G120-CU240B-E-2, G120C, G120D
FBLOCKS: Execution cycle group entry rejected
converter
Meaning: At least one execution cycle group was rejected when the execution cycle groups of the free function blocks were registered with the sampling time manager. Too many different hardware sampling times may have been assigned to the free function blocks.
Possible causes
Source: SINAMICS G110M P757; SINAMICS G120, Control Unit CU240B-2_CU240E-2 P798; SINAMICS G120C P726; SINAMICS G120D Control Unit CU240D- 2_CU250D- 2 P956
Series: G115D
FBLOCKS: Execution cycle group entry rejected
converter
Meaning:
Possible causes
Source: SINAMICS G115D P816
Series: G120-CU250S-2
FBLOCKS: Entry of the execution cycle group was rejected.
converter
Meaning: At least one execution cycle group was rejected when the execution cycle groups of the free function blocks were registered with the sampling time manager. Too many different hardware sampling times may have been assigned to the free function blocks.
Possible causes
Source: SINAMICS G120, Control Unit CU250S-2 P1626
Series: G120X, G120XA
FBLOCKS: Execution cycle group entry rejected
converter
Meaning: At least one execution cycle group was rejected when the execution cycle groups for the free function blocks were registered with the sampling time manager. Too many different hardware sampling times may have been assigned to the free function blocks. See also: r20008 (available hardware sampling times).
Possible causes
Source: SINAMICS G120X converter P1421; SINAMICS G120XA PN converter P1330
Series: S110
FBLOCKS: Execution cycle group entry rejected
servo drive
Meaning: When registering the execution cycle groups of the free function blocks with the sampling time manager, at least one execution cycle group was rejected. Too many different hardware sampling times may have been assigned to the free function blocks. See: r20008 (available hardware sampling times).
Possible causes
Source: SINAMICS S110 P1182