Siemens F40895 fault code meaning
Siemens / F40895
Series: DCM-6RA80
CX32 DRIVE-CLiQ(CU): Cyclic data transfer fault
DC drive
Meaning: %2 Message class: Internal communication (DRIVE-CLiQ) fault (12) Drive object: DC_CTRL, DC_CTRL_R, DC_CTRL_R_S, DC_CTRL_S, TM150, TM15DI_DO, TM31 Component: DRIVE-CLiQ stroke module (Hub) Propagation: LOCAL Response: OFF2 Acknowledgment: Immediate Cause: DRIVE-CLiQ communication between the control unit and the associated extension controller is faulty. Fault cause: 11 (= 0B hexadecimal): Synchronization error during alternating cyclic data transfer. Note on the message value: Detailed information is encoded in the message value (r0949/r2124) as follows: 0000yyxx hexadecimal: yy = component number, xx = fault cause
Possible causes
Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P1203
Series: G120-CU250S-2
CX32 DRIVE-CLiQ(CU): Cyclic data transfer fault
converter
Meaning:
Possible causes
Source: SINAMICS G120, Control Unit CU250S-2 P1625
Series: G130-G150, S120-S150
CX32 DRIVE-CLiQ(CU): Cyclic data transfer fault
converter
Meaning: %2 Message class: Internal communication (DRIVE-CLiQ) Fault (12) Drive object: All objects Component: DRIVE-CLiQ Stroke Module (Hub) Propagation: LOCAL Reaction: OFF2 Acknowledgment: Immediate Cause: Fault in DRIVE-CLiQ communication between the Control Unit and the associated extension controller. Fault cause: 11 (= 0B hexadecimal): Synchronization error during data transfer in alternating cycles. Note on the message value: Detailed information is encoded in the message value (r0949/r2124) as follows: 0000yyxx hexadecimal: yy = Component number, xx = Fault cause
Possible causes
Source: SINAMICS G130_G150 P2008; SINAMICS S120_S150 P3225