Siemens F36896 fault code meaning
Siemens / F36896
Series: G120-CU250S-2
DRIVE-CLiQ hub(CU): Component characteristics mismatch
converter
Meaning: Compared with its state during boot-up, the characteristics of the DRIVE-CLiQ component (DRIVE-CLiQ hub module) indicated by the fault value have become incompatible. For example, this may be due to replacement of the DRIVE-CLiQ cable or the DRIVE-CLiQ component.
Possible causes
Source: SINAMICS G120, control unit CU250S-2 P1602
Series: G130-G150
CU DRIVE-CLiQ: Inconsistent component characterist
converter
Meaning:
Possible causes
Source: G150 P1005
Series: S120-S150
DRIVE-CLiQ hub(CU): Component characteristics mismatch
converter
Meaning:
Possible causes
Source: SINAMICS S120_S150 P3196
Series: S220
DRIVE-CLiQ hub (CU): Component characteristics mismatch
converter
Meaning: The characteristics of the DRIVE-CLiQ component (DRIVE-CLiQ hub module) indicated by the fault value have become incompatible compared with those during the boot process. For example, this may be due to replacement of the DRIVE-CLiQ cable or the DRIVE-CLiQ component.
Possible causes
Source: SINAMICS S220 Converter P2744