Siemens F36886 fault code meaning

Siemens / F36886

Series: DCM-6RA80

DRIVE-CLiQ hub (CU): Error sending DRIVE-CLiQ data

DC drive

Meaning: %2 Message class: Internal communication (DRIVE-CLiQ) fault (12) Drive object: DC_CTRL, DC_CTRL_R, DC_CTRL_R_S, DC_CTRL_S, TM150, TM15DI_DO, TM31 Component: Terminal board (TB) Propagation: LOCAL Response: None Acknowledgment: Immediate Cause: A DRIVE-CLiQ communication fault exists between the control unit and the associated DRIVE-CLiQ hub module. Data cannot be sent. Fault cause: 65 (= 41 hexadecimal): Telegram type mismatch with the send list. Note on the message value: Detailed information is encoded in the message value (r0949/r2124) as follows: 0000yyxx hexadecimal: yy = component number, xx = fault cause

Possible causes

Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P1193

Series: G120-CU250S-2

DRIVE-CLiQ hub (CU): Error sending DRIVE-CLiQ data

converter

Meaning:

Possible causes

Source: SINAMICS G120, Control Unit CU250S-2 P1098

Series: G130-G150

DRIVE-CLiQ hub (CU): Error sending DRIVE-CLiQ data

converter

Meaning: %2 Message class: Internal communication (DRIVE-CLiQ) Fault (12) Drive object: B_INF, HUB, TM120, TM150, TM31, VECTOR_G Component: Terminal Board (TB) Propagation: LOCAL Reaction: None Acknowledgment: Immediate Cause: Fault in DRIVE-CLiQ communication between the Control Unit and the associated DRIVE-CLiQ Hub Module. Data cannot be sent. Fault cause: 65 (= 41 hexadecimal): Telegram type mismatch with the send list. Note on the message value: Detailed information is encoded in the message value (r0949/r2124) as follows: 0000yyxx hexadecimal: yy = Component number, xx = Fault cause

Possible causes

Source: SINAMICS G130_G150 P1997