Siemens F36837 fault code meaning

Siemens / F36837

Series: G130-G150

DRIVE-CLiQ hub: Component fault

converter

Meaning: %2 Message class: Internal communication (DRIVE-CLiQ) Fault (12) Drive object: B_INF, HUB, VECTOR_G Component: Terminal Board (TB) Propagation: LOCAL Reaction: None Acknowledgment: Immediate Cause: A fault was detected on the associated DRIVE-CLiQ component. This may be a hardware fault. Fault causes: 32 (= 20 hexadecimal): Incorrect telegram header. 35 (= 23 hexadecimal): Receive error: Telegram buffer error. 66 (= 42 hexadecimal): Send error: Telegram buffer error. 67 (= 43 hexadecimal): Send error: Telegram buffer error. Note on the message value: Detailed information is encoded in the message value (r0949/r2124) as follows: 0000yyxx hexadecimal: yy = Component number, xx = Fault cause

Possible causes

Source: SINAMICS G130_G150 P1994

Series: S120-S150

DRIVE-CLiQ hub: Component fault

converter

Meaning:

Possible causes

Source: SINAMICS S120_S150 P3192

Series: S210

DRIVE-CLiQ hub: Component fault

servo drive

Meaning: %2 Component: Terminal board (TB) Broadcast: Local Reaction: None Acknowledgment: Immediate Cause: A fault was detected on the associated DRIVE-CLiQ component. This may be a hardware fault. Fault cause: 32 (= 20 hexadecimal): Incorrect message header. 35 (= 23 hexadecimal): Receive error: Fault in the message buffer. 66 (= 42 hexadecimal): Send error: Fault in the message buffer. 67 (= 43 hexadecimal): Send error: Fault in the message buffer. Note on the message value: Details are provided in the message value (r0949/r2124) as follows: 0000yyxx hexadecimal: yy = component number, xx = fault cause.

Possible causes

Source: SINAMICS S210_SIMOTICS S-1FK2 and S-1FT2 P1403