Siemens F36216 fault code meaning

Siemens / F36216

Series: G130-G150, G200, G210, G210X, G220, S120-S150, S220

Hub: 24 V power supply undervoltage fault

converter

Meaning: The 24 V power supply on the DRIVE-CLiQ hub module is below the fault threshold.

Possible causes

Source: SINAMICS G130_G150 P1990; SINAMICS G200 converter P789; SINAMICS G210 converter P1364; SINAMICS G210X converter P1066; SINAMICS G220 converter P1587; SINAMICS S120_S150 P3188; SINAMICS S220 converter P2735

Series: S210

Hub: 24 V power supply undervoltage fault

servo drive

Meaning: The 24 V power supply on the DRIVE-CLiQ hub module is below the fault threshold.

Possible causes