Siemens F35860 fault code meaning
Siemens / F35860
Series: DCM-6RA80
TM DRIVE-CLiQ (CU): Telegram fault
DC drive
Meaning: %2 Message class: Internal communication (DRIVE-CLiQ) fault (12) Drive object: DC_CTRL, DC_CTRL_R, DC_CTRL_R_S, DC_CTRL_S, TM150, TM15DI_DO, TM31 Component: Terminal module (TM) Broadcast: LOCAL Reaction: OFF1 (OFF2) Acknowledgment: Immediate
Possible causes
Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P1180
Series: G120-CU250S-2
TM DRIVE-CLiQ (CU): Telegram fault
converter
Meaning: A DRIVE-CLiQ communication fault has occurred between the control unit and the associated terminal module (TM). Fault causes: 1 (= 01 hexadecimal): Checksum error (CRC error. 2 (= 02 hexadecimal): The telegram is shorter than the specified byte length or the length specified in the receive list. 3 (= 03 hexadecimal): The telegram is longer than the specified byte length or the length specified in the receive list. 4 (= 04 hexadecimal): The received telegram length does not match the receive list. 5 (= 05 hexadecimal): The received telegram type does not match the receive list. 6 (= 06 hexadecimal): Power unit address mismatch between the telegram and the receive list. 9 (= 09 hexadecimal): An incorrect bit is set in the received telegram. 16 (= 10 hexadecimal): The telegram was received too early. 17 (= 11 hexadecimal): CRC error and the telegram was received too early. 18 (= 12 hexadecimal): The telegram is shorter than the specified byte length or the length specified in the receive list, and was received too early. 19 (=
Possible causes
Source: SINAMICS G120, Control Unit CU250S-2 P1143
Series: G130-G150
TM DRIVE-CLiQ (CU): Telegram fault
converter
Meaning: %2 Message class: Internal communication (DRIVE-CLiQ) fault (12) Drive object: B_INF, TM120, TM150, TM31, TM54F_MA, TM54F_SL, VECTOR_G Component: Terminal module (TM) Broadcast: LOCAL Reaction: OFF1 (OFF2) Acknowledgment: Immediate
Possible causes
Source: SINAMICS G130_G150 P1978
Series: S120-S150
TM DRIVE-CLiQ (CU): Telegram fault
converter
Meaning: %2 Message class: Internal communication (DRIVE-CLiQ) fault (12) Drive object: A_INF, B_INF, CU_LINK, HLA, R_INF, S_INF, SERVO, SERVO_AC, SERVO_I_AC, TM120, TM15, TM150, TM15DI_DO, TM17, TM31, TM41, TM54F_MA, TM54F_SL, VECTOR, VECTOR_AC, VECTOR_I_AC Component: Terminal module (TM) Broadcast: LOCAL Reaction: OFF1 (OFF2) Acknowledgment: Immediate
Possible causes
Source: SINAMICS S120_S150 P3175