Siemens F35851 fault code meaning
Siemens / F35851
Series: DCM-6RA80
TM DRIVE-CLiQ (CU): Sign-of-life signal missing
DC drive
Meaning: %2 Message class: Internal communication (DRIVE-CLiQ) fault (12) Drive object: DC_CTRL, DC_CTRL_R, DC_CTRL_R_S, DC_CTRL_S, TM150, TM15DI_DO, TM31 Component: Terminal module (TM) Propagation: LOCAL Response: OFF1 (OFF2) Acknowledgment: Immediate Cause: DRIVE-CLiQ communication between the control unit and the associated terminal module (TM) is faulty. The sign of life from the DRIVE-CLiQ component to the control unit is not set. Fault cause: 10 (= 0A hexadecimal): The sign-of-life bit is not set in the received telegram. Note on the message value: Detailed information is encoded in the message value (r0949/r2124) as follows: 0000yyxx hexadecimal: yy = component number, xx = fault cause
Possible causes
Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P1180
Series: G120-CU250S-2
TM DRIVE-CLiQ (CU): Missing sign-of-life signal
converter
Meaning:
Possible causes
Source: SINAMICS G120, Control Unit CU250S-2 P1143
Series: G130-G150
TM DRIVE-CLiQ (CU): Sign-of-life signal missing
converter
Meaning: %2 Message class: Internal communication (DRIVE-CLiQ) Fault (12) Drive object: B_INF, TM120, TM150, TM31, TM54F_MA, TM54F_SL, VECTOR_G Component: Terminal Module (TM) Propagation: LOCAL Reaction: OFF1 (OFF2) Acknowledgment: Immediate Cause: Fault in DRIVE-CLiQ communication between the Control Unit and the associated Terminal Module (TM). The sign of life from component DRIVE-CLiQ to the Control Unit is not set. Fault cause: 10 (= 0A hexadecimal): The sign-of-life bit is not set in the received telegram. Note on the message value: Detailed information is encoded in the message value (r0949/r2124) as follows: 0000yyxx hexadecimal: yy = Component number, xx = Fault cause
Possible causes
Source: SINAMICS G130_G150 P1978
Series: S120-S150
TM DRIVE-CLiQ (CU): Sign-of-life signal missing
converter
Meaning:
Possible causes
Source: SINAMICS S120_S150 P3175
Series: S220
TM DRIVE-CLiQ (CU): Heartbeat signal missing
converter
Meaning:
Possible causes
Source: SINAMICS S220 converter P2713