Siemens F35230 fault code meaning

Siemens / F35230

Series: DCM-6RA80

TM: Hardware fault

DC drive

Meaning: The terminal module (TM) reports an internal fault. The signals from this component may be erroneous and can no longer be used.

Possible causes

Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P1167

Series: G130-G150, S120-S150

TM: Hardware fault

converter

Meaning: The terminal module (TM) reports an internal fault. The signals from this component may be erroneous and can no longer be used.

Possible causes

Source: SINAMICS G130_G150 P1966; SINAMICS S120_S150 P3160

Series: G210X

TM: Hardware fault

converter

Meaning:

Possible causes

Source: SINAMICS G210X converter P1055

Series: S220

TB: Hardware fault

converter

Meaning: The terminal board in use reports an internal fault. Signals from this component must not be evaluated, as they are likely to be incorrect.

Possible causes

Source: SINAMICS S220 converter P2691