Siemens F35040 fault code meaning

Siemens / F35040

Series: G130-G150

TM54F: 24 V undervoltage

converter

Meaning: %1 bin Message class: Supply voltage fault (undervoltage) (3) Drive object: B_INF, TM54F_MA, TM54F_SL, VECTOR_G Component: Terminal module (TM) Broadcast: GLOBAL Reaction: None Acknowledgment: Immediate Cause: Undervoltage in the 24 V power supply of terminal module 54F (TM54F). As a fault reaction, the fail-safe inputs are transmitted to motion supervision.

Possible causes

Source: SINAMICS G130_G150 P1954

Series: S120-S150

TM54F: 24 V undervoltage

converter

Meaning: %1 bin Message class: Supply voltage fault (undervoltage) (3) Drive object: A_INF, B_INF, HLA, R_INF, S_INF, SERVO, SERVO_AC, SERVO_I_AC, TM41, TM54F_MA, TM54F_SL, VECTOR, VECTOR_AC, VECTOR_I_AC Component: Terminal module (TM) Broadcast: GLOBAL Reaction: None Acknowledgment: Immediate Cause: Undervoltage in the 24 V power supply of terminal module 54F (TM54F). As a fault reaction, the fail-safe inputs are transferred to motion supervision.

Possible causes

Source: SINAMICS S120_S150 P3145