Siemens F34896 fault code meaning
Siemens / F34896
Series: G120-CU250S-2
VSM DRIVE-CLiQ(CU): Component characteristic mismatch
converter
Meaning: Compared with its state at start, the DRIVE-CLiQ component (voltage measurement module) indicated by the fault value has become incompatible. For example, this may be due to replacement of the DRIVE-CLiQ cable or the DRIVE-CLiQ component.
Possible causes
Source: SINAMICS G120, Control Unit CU250S-2 P1594
Series: G130-G150
VSM DRIVE-CLiQ(CU): Component characteristic mismatch
converter
Meaning:
Possible causes
Source: SINAMICS G130_G150 P1942
Series: S120-S150
VSM DRIVE-CLiQ(CU): Component characteristic mismatch
converter
Meaning: The DRIVE-CLiQ component (voltage measurement module) indicated by the fault value has become incompatible compared with its state at start. For example, this may be due to replacement of the DRIVE-CLiQ cable or the DRIVE-CLiQ component.
Possible causes
Source: SINAMICS S120_S150 P3134