Siemens F34836 fault code meaning

Siemens / F34836

Series: G130-G150

VSM DRIVE-CLiQ: DRIVE-CLiQ data send error

converter

Meaning: %2 Message class: Internal communication (DRIVE-CLiQ) fault (12) Drive object: B_INF, VECTOR_G Component: Voltage supervision module (VSM) Broadcast: LOCAL Reaction: Vector: None (OFF1, OFF2) Infeed: OFF2 (OFF1, None) Acknowledgment: Immediate Cause: Fault in DRIVE-CLiQ communication between the control unit and the associated voltage supervision module. Data cannot be sent. Fault cause: 65 (= 41 hexadecimal): Telegram type mismatch with the send list. Note on the message value: Detailed information is encoded in the message value (r0949/r2124) as follows: 0000yyxx hexadecimal: yy = component number, xx = fault cause

Possible causes

Source: SINAMICS G130_G150 P1938

Series: S120-S150

VSM DRIVE-CLiQ: DRIVE-CLiQ data send error

converter

Meaning:

Possible causes

Source: SINAMICS S120_S150 P3129

Series: S220

VSM DRIVE-CLiQ: DRIVE-CLiQ data send error

converter

Meaning:

Possible causes

Source: SINAMICS S220 Converter P2672