Siemens F33895 fault code meaning

Siemens / F33895

Series: G120-CU250S-2

Encoder 3 DRIVE-CLiQ(CU): Cyclic data exchange fault

converter

Meaning: %2 Drive object: CU250S_S, CU250S_S_CAN, CU250S_S_DP, CU250S_S_PN Reaction: OFF1 (IASC/DCBRK, OFF2, OFF3, None) Acknowledgment: Immediate Cause: DRIVE-CLiQ communication between the encoder module (encoder 3) and the control unit is faulty. Fault cause: 11 (= 0B hexadecimal): A synchronization error occurred during cyclic data exchange. Note on the information value: Detailed information is encoded in the information value (r0949/r2124) as follows: 0000yyxx hexadecimal: yy = component number, xx = fault cause

Possible causes

Source: SINAMICS G120, Control Unit CU250S-2 P1585

Series: G130-G150

CU DRIVE-CLiQ: Cyclic data transfer error

converter

Meaning:

Possible causes

Source: G150 P983

Series: S120-S150

Encoder 3 DRIVE-CLiQ(CU): Alternating cyclic data transfer fault

converter

Meaning:

Possible causes

Source: SINAMICS S120_S150 P3117

Series: S220

Encoder 3 DRIVE-CLiQ (CU): Alternating cyclic data transmission error

converter

Meaning:

Possible causes

Source: SINAMICS S220 Converter P2659