Siemens F33875 fault code meaning
Siemens / F33875
Series: DCM-6RA80
Encoder 3: Supply voltage fault
DC drive
Meaning: %2 Message class: Supply voltage fault (undervoltage) (3) Drive object: DC_CTRL, DC_CTRL_R, DC_CTRL_R_S, DC_CTRL_S Component: Sensor Module encoder 3 Propagation: LOCAL Response: OFF1 (IASC/DCBRK, OFF2, OFF3, None) Acknowledgment: Immediate Cause: DRIVE-CLiQ communication between the associated DRIVE-CLiQ component and the control unit reported a supply voltage fault. Fault cause: 9 (= 09 hexadecimal): Component supply voltage fault. Note on the message value: Detailed information is encoded in the message value (r0949/r2124) as follows: 0000yyxx hexadecimal: yy = component number, xx = fault cause
Possible causes
Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P1157