Siemens F33500 fault code meaning

Siemens / F33500

Series: G120-CU250S-2

Encoder 3: Position tracking operating range exceeded

converter

Meaning: On a linear axis without modulo compensation, the drive/encoder exceeded the maximum permissible travel range. When p0411.0 = 1, the maximum travel range of the configured linear axis is 64 times p0421 (+/- 32 times). When p0411.3 = 1, the maximum travel range of the configured linear axis is set to the maximum permissible value, reaching +/-p0412/2 (number of revolutions rounded down). The maximum possible value depends on the line count (p0408) and the fine resolution (p0419).

Possible causes

Source: SINAMICS G120, Control Unit CU250S-2 P1574

Series: G130-G150, S120-S150

Encoder 3: Position tracking operating range exceeded

converter

Meaning: On a linear axis without modulo compensation, the drive/encoder has exceeded the maximum permissible operating range. When p0411.0 = 1, the maximum operating range for the configured linear axis is 64 times p0421 (+/- 32 times). When p0411.3 = 1, the maximum operating range for the configured linear axis is the maximum permissible value, reaching +/-p0412/2 (number of revolutions rounded down). The maximum possible value depends on the line count (p0408) and fine resolution (p0419).

Possible causes

Source: SINAMICS G130_G150 P1913;SINAMICS S120_S150 P3104

Series: G210

Encoder 3: Position tracking operating range exceeded

converter

Meaning:

Possible causes

Source: SINAMICS G210 converter P1339

Series: S220

Encoder 3: Position tracking operating range exceeded

converter

Meaning: On a linear axis without modulo compensation, the drive/encoder exceeded the maximum permissible travel range. When p0411.0 = 1, the maximum travel range of the configured linear axis is 64 times p0421 (+/- 32 times). When p0411.3 = 1, the maximum travel range of the configured linear axis is the maximum permissible value, reaching +/-p0412/2 (number of revolutions rounded down). The maximum possible value depends on the line count (p0408) and the interpolation resolution (p0419).

Possible causes

Source: SINAMICS S220 converter P2645