Siemens F32905 fault code meaning

Siemens / F32905

Series: DCM-6RA80

Encoder 2: Encoder parameter setting error

DC drive

Meaning:

Possible causes

Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P1150

Series: G120-CU250S-2

Encoder 2: Incorrect parameter setting

converter

Meaning: An incorrect parameter has been detected for encoder 2. The set encoder type may also differ from the connected encoder type. The relevant parameter can be identified as follows: - Obtain the parameter number from the fault value (r0949). - Determine the parameter index (p0187).

Possible causes

Source: SINAMICS G120, Control Unit CU250S-2 P1570

Series: G120D

Incorrect parameter settings

converter

Meaning:

Possible causes

Source: Converter SINAMICS G120D, equipped with control units CU240D-2 and CU250D-2 P95

Series: G130-G150

Encoder 2: Parameterization error

converter

Meaning:

Possible causes

Source: G150 P965

Series: S110

Encoder 2: Incorrect parameter setting

servo drive

Meaning: An incorrect parameter has been detected for encoder 2. The set encoder type may also differ from the connected encoder type. The relevant parameter can be identified as follows: - Obtain the parameter number from the fault value (r0949). - Determine the parameter index (p0187).

Possible causes

Source: SINAMICS S110 P1178