Siemens F32896 fault code meaning
Siemens / F32896
Series: G120-CU250S-2
Encoder 2 DRIVE-CLiQ(CU): Component characteristics mismatch
converter
Meaning: The characteristics of the DRIVE-CLiQ component (encoder module for encoder 2) specified by the fault value have become incompatible compared with those at startup. For example, this may be due to replacement of the DRIVE-CLiQ cable or the DRIVE-CLiQ component.
Possible causes
Source: SINAMICS G120, Control Unit CU250S-2 P1569
Series: G130-G150
CU DRIVE-CLiQ: Inconsistent component characterist
converter
Meaning:
Possible causes
Source: G150 P964
Series: G210, G220
Encoder 2 DRIVE-CLiQ: Component characteristic mismatch
converter
Meaning: Compared with its state at start, component DRIVE-CLiQ (the encoder module for encoder 2), identified by the fault value, has become incompatible. For example, this may be due to replacement of the DRIVE-CLiQ cable or the DRIVE-CLiQ component.
Possible causes
Source: SINAMICS G210 converter P1323; SINAMICS G220 converter P1569
Series: S110
Encoder 2 DRIVE-CLiQ(CU): Component characteristics mismatch
servo drive
Meaning: Compared with the start process, the properties of the DRIVE-CLiQ component indicated by the fault value (encoder module for encoder 2) have become incompatible. For example, this may be due to replacement of the DRIVE-CLiQ cable or the DRIVE-CLiQ component.
Possible causes
Source: SINAMICS S110 P1177
Series: S120-S150
Encoder 2 DRIVE-CLiQ(CU): Component characteristics mismatch
converter
Meaning: The properties of component DRIVE-CLiQ (encoder module for encoder 2), identified by the fault value, have changed incompatibly during boot-up. For example, this may be due to replacement of the DRIVE-CLiQ cable or the DRIVE-CLiQ component.
Possible causes
Source: SINAMICS S120_S150 P3067
Series: S220
Encoder 2 DRIVE-CLiQ (CU): Component properties mismatch
converter
Meaning: Compared with its state at start, component DRIVE-CLiQ (the encoder module for encoder 2), identified by the fault value, has become incompatible. For example, this may be due to replacement of the DRIVE-CLiQ cable or the DRIVE-CLiQ component.
Possible causes
Source: SINAMICS S220 Converter P2607