Siemens F32895 fault code meaning
Siemens / F32895
Series: G120-CU250S-2
Encoder 2 DRIVE-CLiQ(CU): Cyclic data exchange fault
converter
Meaning: %2 Drive object: CU250S_S, CU250S_S_CAN, CU250S_S_DP, CU250S_S_PN Reaction: OFF1 (IASC/DCBRK, OFF2, OFF3, None) Acknowledgment: Immediate Cause: DRIVE-CLiQ communication between the encoder module (encoder 2) and the control unit is faulty. Fault cause: 11 (= 0B hexadecimal): A synchronization error occurred during cyclic data exchange. Note on the information value: Detailed information is encoded in the information value (r0949/r2124) as follows: 0000yyxx hexadecimal: yy = component number, xx = fault cause
Possible causes
Source: SINAMICS G120, Control Unit CU250S-2 P1569
Series: G130-G150
CU DRIVE-CLiQ: Cyclic data transfer error
converter
Meaning:
Possible causes
Source: G150 P964
Series: S110
Encoder 2 DRIVE-CLiQ(CU): Cyclic data exchange fault
servo drive
Meaning: %2 Drive object: SERVO_S110-CAN, SERVO_S110-DP, SERVO_S110-PN Reaction: OFF1 (IASC/ DC brake, OFF2, OFF3, none) Acknowledgment: Immediate Cause: DRIVE-CLiQ communication between the encoder module (encoder 2) and the control unit is faulty.
Possible causes
Source: SINAMICS S110 P1177
Series: S120-S150
Encoder 2 DRIVE-CLiQ(CU): Alternating cyclic data transfer fault
converter
Meaning: %2 Message class: Internal communication (DRIVE-CLiQ) fault (12) Drive object: HLA, SERVO, SERVO_AC, SERVO_I_AC, VECTOR, VECTOR_AC, VECTOR_I_AC Component: Sensor Module, encoder 2 Broadcast: LOCAL Reaction: Servo: OFF1 (IASC/DCBRK, OFF2, OFF3, None) Vector: OFF1 (IASC/DCBRK, OFF2, OFF3, None) Hla: OFF1 (OFF2, OFF3, None) Acknowledgment: Immediate Cause: DRIVE-CLiQ communication between the encoder module (encoder 2) and the Control Unit is faulty. Fault cause: 11 (= 0B hexadecimal): Synchronization error during data transfer in alternating cycles. Note on the message value: Detailed information is encoded in the message value (r0949/r2124) as follows: 0000yyxx hexadecimal: yy = component number, xx
Possible causes
Source: SINAMICS S120_S150 P3067