Siemens F32813 fault code meaning

Siemens / F32813

Series: DCM-6RA80

Encoder 2: Hardware logic unit fault

DC drive

Meaning: %1 bin Message class: Hardware/software fault (1) Drive object: DC_CTRL, DC_CTRL_R, DC_CTRL_R_S, DC_CTRL_S Component: Sensor Module encoder 2 Propagation: GLOBAL Response: OFF1 (IASC/DCBRK, OFF2, OFF3, None) Acknowledgment: Pulse inhibit Cause: DRIVE-CLiQ Encoder logic unit fault.

Possible causes

Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P1141

Series: G120-CU250S-2

Encoder 2: Hardware logic unit fault

converter

Meaning: %1 bin Drive object: CU250S_S, CU250S_S_CAN, CU250S_S_DP, CU250S_S_PN Reaction: OFF1 (IASC/DCBRK, OFF2, OFF3, None) Acknowledgment: Pulse inhibited. Cause: DRIVE-CLiQ The encoder fault word indicates the fault bits that are set.

Possible causes

Source: SINAMICS G120, Control Unit CU250S-2 P1562

Series: G130-G150

Encoder 2: Hardware logic unit fault

converter

Meaning: %1 bin Message class: Hardware/software fault (1) Drive object: VECTOR_G Component: Sensor Module encoder 2 Broadcast: GLOBAL Reaction: OFF1 (IASC/DCBRK, OFF2, OFF3, None) Acknowledgment: Inhibit pulses Cause: Fault in the logic unit of encoder DRIVE-CLiQ.

Possible causes

Source: SINAMICS G130_G150 P1871

Series: G220

Encoder 2: Hardware logic unit fault

converter

Meaning: %1 bin Component: Encoder module 2 Reaction: OFF1 (IASC/DCBRK, OFF2, OFF3, None) Acknowledgment: Pulse inhibit Cause: Logic unit fault in the DRIVE-CLiQ encoder.

Possible causes

Source: SINAMICS G220 converter P1560

Series: S110

Encoder 2: Hardware logic unit fault

servo drive

Meaning: %1 bin Drive object: SERVO_S110-CAN, SERVO_S110-DP, SERVO_S110-PN Reaction: OFF1 (IASC/ DC brake, OFF2, OFF3, none). Acknowledgment: Pulse inhibit. Cause: The fault word of encoder DRIVE-CLiQ provides a set fault bit.

Possible causes

Source: SINAMICS S110 P1171

Series: S120-S150

Encoder 2: Hardware logic unit fault

converter

Meaning: %1 bin Message class: Hardware/software fault (1) Drive object: HLA, SERVO, SERVO_AC, SERVO_I_AC, VECTOR, VECTOR_AC, VECTOR_I_AC Component: Sensor Module, encoder 2 Broadcast: GLOBAL Reaction: Servo: OFF1 (IASC/DCBRK, OFF2, OFF3, None) Vector: OFF1 (IASC/DCBRK, OFF2, OFF3, None) Hla: OFF1 (OFF2, OFF3, None) Acknowledgment: Pulse inhibit Cause: Logic unit fault in encoder DRIVE-CLiQ.

Possible causes

Source: SINAMICS S120_S150 P3059

Series: S210

Encoder 2: Hardware logic unit fault

servo drive

Meaning: %1 bin Component: Encoder module 2 Broadcast: Global Reaction: OFF1 Acknowledgment: Pulse inhibit Cause: DRIVE-CLiQ Encoder logic unit fault.

Possible causes

Source: SINAMICS S210_SIMOTICS S-1FK2 and S-1FT2 P1399

Series: S220

Encoder 2: Hardware logic unit fault

converter

Meaning: %1 bin Model: servo, vector Component: encoder module 2 Propagation: global Reaction: OFF1 (IASC/DCBRK, OFF2, OFF3, none) Acknowledgment: pulse inhibit Cause: DRIVE-CLiQ Fault in the encoder logic unit.

Possible causes

Source: SINAMICS S220 converter P2598