Siemens F32813 fault code meaning
Siemens / F32813
Series: DCM-6RA80
Encoder 2: Hardware logic unit fault
DC drive
Meaning: %1 bin Message class: Hardware/software fault (1) Drive object: DC_CTRL, DC_CTRL_R, DC_CTRL_R_S, DC_CTRL_S Component: Sensor Module encoder 2 Propagation: GLOBAL Response: OFF1 (IASC/DCBRK, OFF2, OFF3, None) Acknowledgment: Pulse inhibit Cause: DRIVE-CLiQ Encoder logic unit fault.
Possible causes
Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P1141
Series: G120-CU250S-2
Encoder 2: Hardware logic unit fault
converter
Meaning: %1 bin Drive object: CU250S_S, CU250S_S_CAN, CU250S_S_DP, CU250S_S_PN Reaction: OFF1 (IASC/DCBRK, OFF2, OFF3, None) Acknowledgment: Pulse inhibited. Cause: DRIVE-CLiQ The encoder fault word indicates the fault bits that are set.
Possible causes
Source: SINAMICS G120, Control Unit CU250S-2 P1562
Series: G130-G150
Encoder 2: Hardware logic unit fault
converter
Meaning: %1 bin Message class: Hardware/software fault (1) Drive object: VECTOR_G Component: Sensor Module encoder 2 Broadcast: GLOBAL Reaction: OFF1 (IASC/DCBRK, OFF2, OFF3, None) Acknowledgment: Inhibit pulses Cause: Fault in the logic unit of encoder DRIVE-CLiQ.
Possible causes
Source: SINAMICS G130_G150 P1871
Series: G220
Encoder 2: Hardware logic unit fault
converter
Meaning: %1 bin Component: Encoder module 2 Reaction: OFF1 (IASC/DCBRK, OFF2, OFF3, None) Acknowledgment: Pulse inhibit Cause: Logic unit fault in the DRIVE-CLiQ encoder.
Possible causes
Source: SINAMICS G220 converter P1560
Series: S110
Encoder 2: Hardware logic unit fault
servo drive
Meaning: %1 bin Drive object: SERVO_S110-CAN, SERVO_S110-DP, SERVO_S110-PN Reaction: OFF1 (IASC/ DC brake, OFF2, OFF3, none). Acknowledgment: Pulse inhibit. Cause: The fault word of encoder DRIVE-CLiQ provides a set fault bit.
Possible causes
Source: SINAMICS S110 P1171
Series: S120-S150
Encoder 2: Hardware logic unit fault
converter
Meaning: %1 bin Message class: Hardware/software fault (1) Drive object: HLA, SERVO, SERVO_AC, SERVO_I_AC, VECTOR, VECTOR_AC, VECTOR_I_AC Component: Sensor Module, encoder 2 Broadcast: GLOBAL Reaction: Servo: OFF1 (IASC/DCBRK, OFF2, OFF3, None) Vector: OFF1 (IASC/DCBRK, OFF2, OFF3, None) Hla: OFF1 (OFF2, OFF3, None) Acknowledgment: Pulse inhibit Cause: Logic unit fault in encoder DRIVE-CLiQ.
Possible causes
Source: SINAMICS S120_S150 P3059
Series: S210
Encoder 2: Hardware logic unit fault
servo drive
Meaning: %1 bin Component: Encoder module 2 Broadcast: Global Reaction: OFF1 Acknowledgment: Pulse inhibit Cause: DRIVE-CLiQ Encoder logic unit fault.
Possible causes
Source: SINAMICS S210_SIMOTICS S-1FK2 and S-1FT2 P1399
Series: S220
Encoder 2: Hardware logic unit fault
converter
Meaning: %1 bin Model: servo, vector Component: encoder module 2 Propagation: global Reaction: OFF1 (IASC/DCBRK, OFF2, OFF3, none) Acknowledgment: pulse inhibit Cause: DRIVE-CLiQ Fault in the encoder logic unit.
Possible causes
Source: SINAMICS S220 converter P2598