Siemens F32500 fault code meaning

Siemens / F32500

Series: DCM-6RA80

Encoder 2: Position tracking operating range exceeded

DC drive

Meaning: On a linear axis without modulo compensation, the drive/encoder has exceeded the maximum permissible travel range. When p0411.0 = 1, the maximum travel range for the configured linear axis is p0421 multiplied by 64 (+/- 32 times). When p0411.3 = 1, the maximum travel range for the configured linear axis is the maximum permissible value, up to +/-p0412/2 (number of revolutions rounded down). The maximum possible value depends on the line count (p0408) and the fine resolution (p0419).

Possible causes

Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P1136

Series: G120-CU250S-2

Encoder 2: Position tracking operating range exceeded

converter

Meaning: On a linear axis without modulo compensation, the drive/encoder exceeded the maximum permissible travel range. When p0411.0 = 1, the maximum travel range of the configured linear axis is 64 times p0421 (+/- 32 times). When p0411.3 = 1, the maximum travel range of the configured linear axis is set to the maximum permissible value, reaching +/-p0412/2 (number of revolutions rounded down). The maximum possible value depends on the line count (p0408) and the fine resolution (p0419).

Possible causes

Source: SINAMICS G120, Control Unit CU250S-2 P1558

Series: G130-G150, S120-S150

Encoder 2: Position tracking operating range exceeded

converter

Meaning: On a linear axis without modulo compensation, the drive/encoder has exceeded the maximum permissible operating range. When p0411.0 = 1, the maximum operating range for the configured linear axis is 64 times p0421 (+/- 32 times). When p0411.3 = 1, the maximum operating range for the configured linear axis is the maximum permissible value, reaching +/-p0412/2 (number of revolutions rounded down). The maximum possible value depends on the line count (p0408) and fine resolution (p0419).

Possible causes

Source: SINAMICS G130_G150 P1866;SINAMICS S120_S150 P3054

Series: G220

Encoder 2: Position tracking operating range exceeded

converter

Meaning: On a linear axis without modulo compensation, the drive/encoder exceeded the maximum permissible travel range. When p0411.0 = 1, the maximum travel range on the configured linear axis is 64 times p0421 (+/- 32 times). When p0411.3 = 1, the maximum travel range on the configured linear axis is the maximum permissible value, reaching +/-p0412/2 (number of revolutions rounded down). The maximum possible value depends on the line count (p0408) and the fine resolution (p0419). Faults and alarms 5.2 List of faults and alarms SINAMICS G220 Converter 1552 Parameter Manual, 07/2026, FW V6.7, A5E51781505C AD

Possible causes

Source: SINAMICS G220 Converter P1554

Series: S110

Encoder 2: Position tracking operating range exceeded

servo drive

Meaning: On a linear axis without modulo compensation, the drive/encoder has exceeded the maximum permissible operating range. When p0411.0 = 1, the maximum operating range for the configured linear axis is 64 times p0421 (+/- 32 times). When p0411.3 = 1, the maximum operating range for the configured linear axis is the maximum permissible value, reaching +/-p0412/2 (number of revolutions rounded down). The maximum possible value depends on the line count (p0408) and fine resolution (p0419).

Possible causes

Source: SINAMICS S110 P1168

Series: S220

Encoder 2: Position tracking operating range exceeded

converter

Meaning:

Possible causes

Source: SINAMICS S220 converter P2592