Siemens F32160 fault code meaning

Siemens / F32160

Series: DCM-6RA80

Encoder 2: Analog encoder channel A fault

DC drive

Meaning: The analog encoder input voltage exceeded the permissible limits.

Possible causes

Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P1125

Series: G120-CU240B-E-2, G120-CU250S-2, G130-G150

Encoder 2: Analog encoder channel A fault

converter

Meaning: The analog encoder input voltage exceeded the permissible limits.

Possible causes

Source: SINAMICS G120, Control Unit CU240B-2_CU240E-2 P790; SINAMICS G120, Control Unit CU250S-2 P1548; SINAMICS G130_G150 P1855

Series: S110, S200

Encoder 2: Analog encoder channel A fault

servo drive

Meaning: The analog encoder input voltage exceeded the permissible limits.

Possible causes

Source: SINAMICS S110 P1158; SINAMICS S200 Spindle Drive P466

Series: S120-S150

Encoder 2: Analog encoder channel A fault

converter

Meaning:

Possible causes

Source: SINAMICS S120_S150 P3042