Siemens F32129 fault code meaning

Siemens / F32129

Series: G120-CU250S-2

Encoder 2: Position difference between Hall sensor/signal C/D and signal A/B too large

converter

Meaning: Signal C/D error: greater than +/-15 ° mechanical angle or greater than +/-60° electrical angle; or Hall signal error: greater than +/-60 ° electrical angle. The period of signal C/D equals 360 ° mechanical angle. The period of the Hall signal equals 360 ° electrical angle. For example, monitoring responds if the Hall sensor used in place of signal C/D is connected for the wrong direction of rotation or sends inaccurate values. After fine synchronization using 1 or 2 reference marks of a distance-coded encoder, this fault is no longer triggered; alarm A32429 is triggered instead.

Possible causes

Source: SINAMICS G120, Control Unit CU250S-2 P1073