Siemens / F32103

Series: G120-CU250S-2

Encoder 2: Signal R amplitude error

converter

Meaning: The amplitude of the zero pulse signal (signal R) of encoder 2 is outside the tolerance range. This fault may be caused by exceeding the "unipolar" voltage level (RP/RN) or by insufficient differential amplitude.

Possible causes

Source: SINAMICS G120, Control Unit CU250S-2 P1136

Series: G130-G150

Encoder 2: Zero pulse signal level (signal R) outside tolerance range

converter

Meaning:

Possible causes

Source: SINAMICS G130_G150 P1838

Series: S110

Encoder 2: Signal R amplitude error

servo drive

Meaning: The amplitude of the zero pulse signal (signal R) of encoder 2 is outside the tolerance range. This fault may be caused by exceeding the "unipolar" voltage level (RP/RN) or by insufficient differential amplitude.

Possible causes