Siemens F32101 fault code meaning

Siemens / F32101

Series: DCM-6RA80

Encoder 2: Zero pulse fault

DC drive

Meaning:

Possible causes

Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P1108

Series: G120-CU250S-2, G130-G150

Encoder 2: Zero pulse fault

converter

Meaning: The distance has exceeded 1.5 times the set zero pulse distance. Set the zero pulse distance for zero pulse monitoring in p0425 (rotary encoder) or p0424 (linear encoder).

Possible causes

Source: SINAMICS G120, Control Unit CU250S-2 P1066; SINAMICS G130_G150 P1838

Series: S110

Encoder 2: Zero pulse fault

servo drive

Meaning: The distance has exceeded 1.5 times the set zero pulse distance. Set the zero pulse distance for zero pulse monitoring in p0425 (rotary encoder) or p0424 (linear encoder).

Possible causes

Source: SINAMICS S110 P1147