Siemens F31916 fault code meaning
Siemens / F31916
Series: G120-CU250S-2
Encoder 1: Parameter setting error
converter
Meaning: An incorrect parameter was detected for encoder 1. The configured encoder type may also differ from the connected encoder type. The relevant parameter can be identified as follows: - Obtain the parameter number from the fault value (r0949). - Determine the parameter index (p0187).
Possible causes
Source: SINAMICS G120, Control Unit CU250S-2 P1534
Series: G130-G150
Encoder 1: Encoder parameter setting error
converter
Meaning: An incorrect parameter was detected for encoder 1. There may be a mismatch between the encoder type (rotary/linear) selected in drive object ENCODER and the configured function module (r0108.12). The relevant parameter can be identified as follows: - Obtain the parameter number from the fault value (r0949). - Determine the parameter index (p0187).
Possible causes
Source: SINAMICS G130_G150 P1835
Series: G210, S220
Motor encoder: Incorrect encoder parameter setting
converter
Meaning: An incorrect encoder parameter has been detected. The encoder type specified in the parameter settings may also differ from the type of encoder actually connected. The relevant parameter can be identified as follows: - Check the fault value (r0949) to obtain the number of the incorrect parameter. - Determine the parameter index (p0187).
Possible causes
Source: SINAMICS G210 converter P1277; SINAMICS S220 converter P2559