Siemens F31896 fault code meaning

Siemens / F31896

Series: G120-CU250S-2

Encoder 1 DRIVE-CLiQ(CU): Component characteristics mismatch

converter

Meaning: The characteristics of the DRIVE-CLiQ component (encoder module for encoder 1) specified in the fault value have become incompatible compared with those at startup. For example, this may be due to replacement of the DRIVE-CLiQ cable or the DRIVE-CLiQ component.

Possible causes

Source: SINAMICS G120, Control Unit CU250S-2 P1531

Series: G130-G150, S120-S150

Encoder 1 DRIVE-CLiQ(CU): Component characteristics mismatch

converter

Meaning: Compared with the start sequence, the characteristics of the DRIVE-CLiQ component (encoder module for encoder 1) specified in the fault value have become incompatible. For example, this may be due to replacement of the DRIVE-CLiQ cable or the DRIVE-CLiQ component.

Possible causes

Source: SINAMICS G130_G150 P1831; SINAMICS S120_S150 P3016

Series: G210, G220

Motor encoder DRIVE-CLiQ: Component characteristic mismatch

converter

Meaning: The DRIVE-CLiQ component (encoder module for the motor encoder) indicated by the fault value has become incompatible compared with its state at start. For example, this may be due to replacement of the DRIVE-CLiQ cable or the DRIVE-CLiQ component.

Possible causes

Source: SINAMICS G210 converter P1273; SINAMICS G220 converter P1523

Series: S110

Encoder 1 DRIVE-CLiQ(CU): Component characteristics mismatch

servo drive

Meaning: Compared with the start sequence, the characteristics of the DRIVE-CLiQ component (encoder module for encoder 1) specified in the fault value have become incompatible. For example, this may be due to replacement of the DRIVE-CLiQ cable or the DRIVE-CLiQ component.

Possible causes

Source: SINAMICS S110 P1143

Series: S210

Motor encoder DRIVE-CLiQ (CU): Component properties mismatch

servo drive

Meaning: Compared with the configuration at start, the DRIVE-CLiQ component indicated by the fault value (encoder module for the motor encoder) has become incompatible. For example, this may be due to replacement of the DRIVE-CLiQ cable or the DRIVE-CLiQ component.

Possible causes

Source: SINAMICS S210_SIMOTICS S-1FK2 and S-1FT2 P1391