Siemens F31896 fault code meaning
Siemens / F31896
Series: G120-CU250S-2
Encoder 1 DRIVE-CLiQ(CU): Component characteristics mismatch
converter
Meaning: The characteristics of the DRIVE-CLiQ component (encoder module for encoder 1) specified in the fault value have become incompatible compared with those at startup. For example, this may be due to replacement of the DRIVE-CLiQ cable or the DRIVE-CLiQ component.
Possible causes
Source: SINAMICS G120, Control Unit CU250S-2 P1531
Series: G130-G150, S120-S150
Encoder 1 DRIVE-CLiQ(CU): Component characteristics mismatch
converter
Meaning: Compared with the start sequence, the characteristics of the DRIVE-CLiQ component (encoder module for encoder 1) specified in the fault value have become incompatible. For example, this may be due to replacement of the DRIVE-CLiQ cable or the DRIVE-CLiQ component.
Possible causes
Source: SINAMICS G130_G150 P1831; SINAMICS S120_S150 P3016
Series: G210, G220
Motor encoder DRIVE-CLiQ: Component characteristic mismatch
converter
Meaning: The DRIVE-CLiQ component (encoder module for the motor encoder) indicated by the fault value has become incompatible compared with its state at start. For example, this may be due to replacement of the DRIVE-CLiQ cable or the DRIVE-CLiQ component.
Possible causes
Source: SINAMICS G210 converter P1273; SINAMICS G220 converter P1523
Series: S110
Encoder 1 DRIVE-CLiQ(CU): Component characteristics mismatch
servo drive
Meaning: Compared with the start sequence, the characteristics of the DRIVE-CLiQ component (encoder module for encoder 1) specified in the fault value have become incompatible. For example, this may be due to replacement of the DRIVE-CLiQ cable or the DRIVE-CLiQ component.
Possible causes
Source: SINAMICS S110 P1143
Series: S210
Motor encoder DRIVE-CLiQ (CU): Component properties mismatch
servo drive
Meaning: Compared with the configuration at start, the DRIVE-CLiQ component indicated by the fault value (encoder module for the motor encoder) has become incompatible. For example, this may be due to replacement of the DRIVE-CLiQ cable or the DRIVE-CLiQ component.
Possible causes
Source: SINAMICS S210_SIMOTICS S-1FK2 and S-1FT2 P1391