Siemens F31805 fault code meaning

Siemens / F31805

Series: G120-CU250S-2

Encoder 1: EPROM checksum incorrect

converter

Meaning: Internal parameter data is damaged.

Possible causes

Source: SINAMICS G120, Control Unit CU250S-2 P1521

Series: G120D

Encoder 1: EEPROM checksum incorrect

converter

Meaning: Internal parameter data is damaged.

Possible causes

Source: SINAMICS G120D Control Unit CU240D- 2_CU250D- 2 P945

Series: G130-G150

Encoder 1: EPROM checksum error

converter

Meaning:

Possible causes

Source: G150 P940

Series: S200, S210

Motor encoder: EEPROM checksum error

servo drive

Meaning: Internal data in EEPROM is corrupted.

Possible causes

Source: SINAMICS S200 PROFINET_SIMOTICS S-1FL2 P586; SINAMICS S210_SIMOTICS S-1FK2 and S-1FT2 P1383